{"title":"Carotid Intima Media Thickness in Nondiabetic Hypertensive Nigerians: Role of Fasting and Postprandial Blood Glucose.","authors":"B N Okeahialam, S A Muoneme, H O Kolade-Yunusa","doi":"10.1155/2016/1429451","DOIUrl":null,"url":null,"abstract":"<p><p>Background/Aims. Carotid intima media thickness (CIMT) tracks atherosclerotic vascular disease. Hypertension and diabetes chiefly contribute to atherosclerosis with 75% of symptomatic cardiovascular disease cases having dysglycaemia even in normal cases. Hypothesising that postprandial hyperglycaemia contributes to cardiovascular morbidity, we sought to determine if any relationship existed between glycaemic profile in nondiabetic hypertensives and atherosclerosis. Methods. In a study of CIMT in nondiabetic, statin-naïve hypertensives, we evaluated fasting blood glucose (FBG) and 2-hour postprandial sugar (2hPPBG) in the patients and compared them with the CIMT. CIMT was measured on both sides, 1 cm proximal to the carotid bulb using a 7.5 mHz transducer of ALOKA SSD-3500 ultrasound machine. Results. The subjects with complete data were 86 (63 F). The mean (SD) of CIMT was 0.89 (0.15) mm, FBG 4.8 (0.097) mmol/L, and 2hPPBG 6.5 (1.81) mmol/L. There was no significant correlation between FBG and 2hPPBG with CIMT. Blood pressure had no bearing on this. When blood glucose data were divided into quartiles and post hoc multiple comparison was done, there was significant difference in CIMT for the different ranges. This was not so for 2hPPBG. Conclusion. Though expected from other studies, we did not show any significant correlation between FBG and 2hPPBG status and CIMT. This may be our pattern as the degree of excursion of 2hPPBG was low. There may be a threshold level above which PPBG starts to impact CIMT. </p>","PeriodicalId":14448,"journal":{"name":"International Journal of Vascular Medicine","volume":"2016 ","pages":"1429451"},"PeriodicalIF":2.5000,"publicationDate":"2016-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1155/2016/1429451","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Vascular Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1155/2016/1429451","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2016/4/10 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"PERIPHERAL VASCULAR DISEASE","Score":null,"Total":0}
引用次数: 2
Abstract
Background/Aims. Carotid intima media thickness (CIMT) tracks atherosclerotic vascular disease. Hypertension and diabetes chiefly contribute to atherosclerosis with 75% of symptomatic cardiovascular disease cases having dysglycaemia even in normal cases. Hypothesising that postprandial hyperglycaemia contributes to cardiovascular morbidity, we sought to determine if any relationship existed between glycaemic profile in nondiabetic hypertensives and atherosclerosis. Methods. In a study of CIMT in nondiabetic, statin-naïve hypertensives, we evaluated fasting blood glucose (FBG) and 2-hour postprandial sugar (2hPPBG) in the patients and compared them with the CIMT. CIMT was measured on both sides, 1 cm proximal to the carotid bulb using a 7.5 mHz transducer of ALOKA SSD-3500 ultrasound machine. Results. The subjects with complete data were 86 (63 F). The mean (SD) of CIMT was 0.89 (0.15) mm, FBG 4.8 (0.097) mmol/L, and 2hPPBG 6.5 (1.81) mmol/L. There was no significant correlation between FBG and 2hPPBG with CIMT. Blood pressure had no bearing on this. When blood glucose data were divided into quartiles and post hoc multiple comparison was done, there was significant difference in CIMT for the different ranges. This was not so for 2hPPBG. Conclusion. Though expected from other studies, we did not show any significant correlation between FBG and 2hPPBG status and CIMT. This may be our pattern as the degree of excursion of 2hPPBG was low. There may be a threshold level above which PPBG starts to impact CIMT.