VivaSight Single-Lumen Tube Combined With Hyperangulated Videolaryngoscopy to Rescue Failed Tracheal Intubation in a Patient With Goldenhar Syndrome: A Case Report.
Emma Möhlenkamp, Eva K Kohse, Phillip B Sasu, Tanja Peters, Jörn Grensemann, Philipp Breitfeld, Martin Petzoldt
{"title":"VivaSight Single-Lumen Tube Combined With Hyperangulated Videolaryngoscopy to Rescue Failed Tracheal Intubation in a Patient With Goldenhar Syndrome: A Case Report.","authors":"Emma Möhlenkamp, Eva K Kohse, Phillip B Sasu, Tanja Peters, Jörn Grensemann, Philipp Breitfeld, Martin Petzoldt","doi":"10.1213/XAA.0000000000001615","DOIUrl":null,"url":null,"abstract":"<p><p>This report describes a patient with Goldenhar syndrome undergoing anesthesia for whom Macintosh videolaryngoscopy failed, as the epiglottis was adhered to the posterior pharynx and could not be lifted with a tracheal introducer (Cormack-Lehane grade 3B). Hyperangulated videolaryngoscopy revealed only the arytenoids (Cormack-Lehane grade 2B), even after direct lifting of the epiglottis, and endotracheal tube advancement failed due to unclear tissue resistance. Hyperangulated videolaryngoscopy was combined with a tube-mounted camera (VivaSight single lumen tube). The combination of both camera perspectives was successfully used to allow placement of the endotracheal tube underneath the epiglottis and through the vocal cords.</p>","PeriodicalId":7307,"journal":{"name":"A&A Practice","volume":null,"pages":null},"PeriodicalIF":0.5000,"publicationDate":"2022-09-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"A&A Practice","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1213/XAA.0000000000001615","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/9/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
This report describes a patient with Goldenhar syndrome undergoing anesthesia for whom Macintosh videolaryngoscopy failed, as the epiglottis was adhered to the posterior pharynx and could not be lifted with a tracheal introducer (Cormack-Lehane grade 3B). Hyperangulated videolaryngoscopy revealed only the arytenoids (Cormack-Lehane grade 2B), even after direct lifting of the epiglottis, and endotracheal tube advancement failed due to unclear tissue resistance. Hyperangulated videolaryngoscopy was combined with a tube-mounted camera (VivaSight single lumen tube). The combination of both camera perspectives was successfully used to allow placement of the endotracheal tube underneath the epiglottis and through the vocal cords.
期刊介绍:
A & A Case Reports, our new online journal publishing Case Reports, related Editorial Commentary, and Correspondence. Anesthesia & Analgesia 1 and Anesthesiology 2 recently announced that they were suspending publication of Case Reports. One reason is that Case Reports typically reduce the Impact Factor of a journal because they are rarely cited. Regardless of the merits of Impact Factor as a metric of journal worth, journals and their editors necessarily consider Impact Factor in strategic planning. At the same time, Case Reports are appreciated by readers for describing “real life” management of difficult or unusual cases not often encountered by practitioners. In a recent issue of Anesthesia & Analgesia, Steven Shafer1 identified many Case Reports whose publication launched productive careers dedicated to solving the puzzle posed by an unusual observation in a single patient.