Determination of cortisol and cortisone in human saliva by a liquid chromatography-tandem mass spectrometry method.

José Gilberto Henriques Vieira, Odete Hirata Nakamura, Valdemir Melechko Carvalho
{"title":"Determination of cortisol and cortisone in human saliva by a liquid chromatography-tandem mass spectrometry method.","authors":"José Gilberto Henriques Vieira,&nbsp;Odete Hirata Nakamura,&nbsp;Valdemir Melechko Carvalho","doi":"10.1590/0004-2730000003347","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>Salivary cortisol measurement plays an important role in the evaluation of adrenal function. Its high correlation with free serum cortisol, the easy of sampling and the limited presence of interfering steroids, generated multiple recent studies of its application, in special in the screening of adrenal hyperfunction. In this paper we present our experience in the development of a high pressure liquid chromatography tandem mass spectrometry (HPLC-MS/MS) method for salivary cortisol and cortisone measurement.</p><p><strong>Materials and methods: </strong>For this study we used 181 saliva samples from our routine diagnostic laboratory. The HPLC-MS/MS method was based on a Waters Quattro Premier tandem mass spectrometer with an electrospray probe. After derivatization with hydroxylamine transitions monitored included cortisol and cortisone. An in-house radioimmunoassay (RIA) was used for salivary cortisol results comparison.</p><p><strong>Results: </strong>Functional sensitivity was 24 ng/dL for cortisol and linearity from 24 to 1929 ng/dL. Saliva cortisol values obtained in the 181 samples presented a median of 52 ng/dL with 5-95% percentile of 24 and 374 ng/dL. With the RIA the results were 86, 25 and 436 ng/dL, respectively, with values for RIA being significantly higher (P<0.0001) and high correlation (r=0.8312, P<0.0001). Cortisone measured in 159 samples showed a median of 278 ng/dL, with 5-95% percentile of 100 and 1,133 ng/dL. Correlation with cortisol values was significant (r=0.820, P<0.0001).</p><p><strong>Conclusion: </strong>We conclude that the HPLC-MS/MS method compares favorably with the RIA for salivary cortisol measurement, with the additional possibility of concomitant cortisone measurement and the evaluation of 11βHSD2 activity.</p>","PeriodicalId":8395,"journal":{"name":"Arquivos brasileiros de endocrinologia e metabologia","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2014-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1590/0004-2730000003347","citationCount":"23","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Arquivos brasileiros de endocrinologia e metabologia","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1590/0004-2730000003347","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 23

Abstract

Objective: Salivary cortisol measurement plays an important role in the evaluation of adrenal function. Its high correlation with free serum cortisol, the easy of sampling and the limited presence of interfering steroids, generated multiple recent studies of its application, in special in the screening of adrenal hyperfunction. In this paper we present our experience in the development of a high pressure liquid chromatography tandem mass spectrometry (HPLC-MS/MS) method for salivary cortisol and cortisone measurement.

Materials and methods: For this study we used 181 saliva samples from our routine diagnostic laboratory. The HPLC-MS/MS method was based on a Waters Quattro Premier tandem mass spectrometer with an electrospray probe. After derivatization with hydroxylamine transitions monitored included cortisol and cortisone. An in-house radioimmunoassay (RIA) was used for salivary cortisol results comparison.

Results: Functional sensitivity was 24 ng/dL for cortisol and linearity from 24 to 1929 ng/dL. Saliva cortisol values obtained in the 181 samples presented a median of 52 ng/dL with 5-95% percentile of 24 and 374 ng/dL. With the RIA the results were 86, 25 and 436 ng/dL, respectively, with values for RIA being significantly higher (P<0.0001) and high correlation (r=0.8312, P<0.0001). Cortisone measured in 159 samples showed a median of 278 ng/dL, with 5-95% percentile of 100 and 1,133 ng/dL. Correlation with cortisol values was significant (r=0.820, P<0.0001).

Conclusion: We conclude that the HPLC-MS/MS method compares favorably with the RIA for salivary cortisol measurement, with the additional possibility of concomitant cortisone measurement and the evaluation of 11βHSD2 activity.

液相色谱-串联质谱法测定人唾液中的皮质醇和可的松。
目的:唾液皮质醇测定在肾上腺功能评价中具有重要作用。它与游离血清皮质醇的高度相关,易于采样和干扰类固醇的存在有限,最近产生了许多关于其应用的研究,特别是在肾上腺功能亢进的筛查中。本文介绍了高压液相色谱串联质谱(HPLC-MS/MS)测定唾液皮质醇和可的松的方法。材料和方法:在本研究中,我们使用了来自常规诊断实验室的181份唾液样本。HPLC-MS/MS方法采用Waters Quattro Premier串联质谱联用电喷雾探针。羟胺衍生化后监测的转化包括皮质醇和可的松。采用放射免疫测定法(RIA)比较唾液皮质醇结果。结果:皮质醇的功能灵敏度为24 ng/dL,线性范围为24 ~ 1929 ng/dL。在181个样本中获得的唾液皮质醇值的中位数为52 ng/dL, 5% -95%的百分位数为24和374 ng/dL。用RIA测定唾液皮质醇的结果分别为86、25和436 ng/dL, RIA的值明显高于RIA(结论:我们认为HPLC-MS/MS方法在唾液皮质醇测量方面优于RIA,并且有可能同时测量可的松和评估11βHSD2的活性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
审稿时长
4-8 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信