Comparison of an accelerometer and a condenser microphone for mechanomyographic signals during measurement of agonist and antagonist muscles in sustained isometric muscle contractions.

IF 3.3 4区 医学 Q1 PHYSIOLOGY
Tae-Kwang Kim, Yoshihiro Shimomura, Koichi Iwanaga, Tetsuo Katsuura
{"title":"Comparison of an accelerometer and a condenser microphone for mechanomyographic signals during measurement of agonist and antagonist muscles in sustained isometric muscle contractions.","authors":"Tae-Kwang Kim,&nbsp;Yoshihiro Shimomura,&nbsp;Koichi Iwanaga,&nbsp;Tetsuo Katsuura","doi":"10.2114/jpa2.27.121","DOIUrl":null,"url":null,"abstract":"<p><p>The purpose of this study was to investigate the influence of the force tremor (FT) on mechanomyographic (MMG) signals recorded by a condenser microphone (MIC) and an accelerometer (ACC) during measurement of agonist and antagonist muscles in sustained isometric contractions. Surface electromyographic (EMG) signals and MMG signals by MIC (MMG-MIC) and ACC (MMG-ACC) were recorded simultaneously on biceps brachii (BB) and triceps brachii (TB). Following determination of the isometric maximum voluntary contraction (MVC), 10 male subjects were asked to perform sustained elbow flexion and extension contractions at 30% MVC until exhaustion. We analyzed the root mean square (RMS) for all signals and compared the sum of the power spectrum (SPA) for 3-6 Hz and 8-12 Hz and the ratio of the sum of SPA for 3-6 Hz and 8-12 Hz in SPA for 3-100 Hz (SPA-FT/SPA-(3-100 Hz)) between MMG-MIC and MMG-ACC. During all sustained muscle contractions, the RMS of EMG and MMG-(MIC) was significantly (p<0.05) increased in antagonistic muscle pairs, while the increase was more noticeable for the agonist than for the antagonist. In addition, the antagonist had a significantly (p<0.05) smaller amplitude than the agonist muscle. The RMS of MMG-ACC, however, showed no significant (p>0.05) difference in RMS amplitude and slope between agonist and antagonist muscles during flexion. In extension, the MMG-ACC-RMS amplitude showed a tendency to be higher in the antagonist than in the agonist, while their slopes showed no significant (p>0.05) difference. The SPA for 3-6 Hz and 8-12 Hz in MMG-(MIC) showed a tendency to be higher in the agonist than the antagonist, and the slopes of the agonist were significantly (p<0.05) higher than those of the antagonist in all contractions. In MMG-ACC, SPA and slopes for 3-6 Hz and 8-12 Hz tended not to differ between agonist and antagonist. The SPA-FT/SPA-(3-100 Hz) in MMG-ACC showed that the antagonist was higher than that of the agonist in all contractions. The MMG-(MIC), however, showed a tendency toward no difference between the agonist and antagonist. In the assessment of muscle activity during simultaneous measurement of the agonist and antagonist during sustained muscle contractions, the MMG signal detected by MIC appeared to be less affected by FT than by ACC due to the different inherent characteristics of the two transducers.</p>","PeriodicalId":48730,"journal":{"name":"Journal of Physiological Anthropology","volume":null,"pages":null},"PeriodicalIF":3.3000,"publicationDate":"2008-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.2114/jpa2.27.121","citationCount":"18","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Physiological Anthropology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.2114/jpa2.27.121","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"PHYSIOLOGY","Score":null,"Total":0}
引用次数: 18

Abstract

The purpose of this study was to investigate the influence of the force tremor (FT) on mechanomyographic (MMG) signals recorded by a condenser microphone (MIC) and an accelerometer (ACC) during measurement of agonist and antagonist muscles in sustained isometric contractions. Surface electromyographic (EMG) signals and MMG signals by MIC (MMG-MIC) and ACC (MMG-ACC) were recorded simultaneously on biceps brachii (BB) and triceps brachii (TB). Following determination of the isometric maximum voluntary contraction (MVC), 10 male subjects were asked to perform sustained elbow flexion and extension contractions at 30% MVC until exhaustion. We analyzed the root mean square (RMS) for all signals and compared the sum of the power spectrum (SPA) for 3-6 Hz and 8-12 Hz and the ratio of the sum of SPA for 3-6 Hz and 8-12 Hz in SPA for 3-100 Hz (SPA-FT/SPA-(3-100 Hz)) between MMG-MIC and MMG-ACC. During all sustained muscle contractions, the RMS of EMG and MMG-(MIC) was significantly (p<0.05) increased in antagonistic muscle pairs, while the increase was more noticeable for the agonist than for the antagonist. In addition, the antagonist had a significantly (p<0.05) smaller amplitude than the agonist muscle. The RMS of MMG-ACC, however, showed no significant (p>0.05) difference in RMS amplitude and slope between agonist and antagonist muscles during flexion. In extension, the MMG-ACC-RMS amplitude showed a tendency to be higher in the antagonist than in the agonist, while their slopes showed no significant (p>0.05) difference. The SPA for 3-6 Hz and 8-12 Hz in MMG-(MIC) showed a tendency to be higher in the agonist than the antagonist, and the slopes of the agonist were significantly (p<0.05) higher than those of the antagonist in all contractions. In MMG-ACC, SPA and slopes for 3-6 Hz and 8-12 Hz tended not to differ between agonist and antagonist. The SPA-FT/SPA-(3-100 Hz) in MMG-ACC showed that the antagonist was higher than that of the agonist in all contractions. The MMG-(MIC), however, showed a tendency toward no difference between the agonist and antagonist. In the assessment of muscle activity during simultaneous measurement of the agonist and antagonist during sustained muscle contractions, the MMG signal detected by MIC appeared to be less affected by FT than by ACC due to the different inherent characteristics of the two transducers.

在持续等长肌肉收缩中测量激动剂和拮抗剂肌肉时,加速度计和电容式传声器测量肌力图信号的比较。
本研究的目的是探讨力颤(FT)对电容传声器(MIC)和加速度计(ACC)测量持续等距收缩时激动剂和拮抗剂肌肉所记录的肌力图(MMG)信号的影响。同时记录肱二头肌(BB)和肱三头肌(TB)的肌表电(EMG)信号和肌动电位(MMG-MIC)和肌动电位(MMG-ACC)信号。在确定等长最大自主收缩(MVC)后,10名男性受试者被要求以30% MVC进行持续的肘关节屈伸收缩,直到筋疲力尽。我们分析了所有信号的均方根(RMS),并比较了MMG-MIC和MMG-ACC之间3-6 Hz和8-12 Hz的功率谱之和(SPA)以及3-100 Hz的SPA中3-6 Hz和8-12 Hz的SPA之和(SPA- ft /SPA-(3-100 Hz))。在所有持续的肌肉收缩过程中,肌电图和MMG-(MIC)的RMS在屈曲时的振幅和斜率在激动剂和拮抗剂肌肉之间有显著差异(p0.05)。此外,MMG-ACC-RMS振幅在拮抗剂组中呈现出高于激动剂组的趋势,但其斜率无显著差异(p>0.05)。在MMG-(MIC)中,3 ~ 6 Hz和8 ~ 12 Hz的SPA呈激动剂高于拮抗剂的趋势,并且激动剂的斜率显著(p
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
6.50%
发文量
39
期刊介绍: Journal of Physiological Anthropology (JPA) is an open access, peer-reviewed journal that publishes research on the physiological functions of modern mankind, with an emphasis on the physical and bio-cultural effects on human adaptability to the current environment. The objective of JPA is to evaluate physiological adaptations to modern living environments, and to publish research from different scientific fields concerned with environmental impact on human life. Topic areas include, but are not limited to: environmental physiology bio-cultural environment living environment epigenetic adaptation development and growth age and sex differences nutrition and morphology physical fitness and health Journal of Physiological Anthropology is the official journal of the Japan Society of Physiological Anthropology.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信