Potentiometric Batch and Flow Injection Analysis of Betaine Hydrochloride

Sayed S. Badawy, Ahmed F. A. Youssef, Ali A. Mutair
{"title":"Potentiometric Batch and Flow Injection Analysis of Betaine Hydrochloride","authors":"Sayed S. Badawy,&nbsp;Ahmed F. A. Youssef,&nbsp;Ali A. Mutair","doi":"10.1002/adic.200790006","DOIUrl":null,"url":null,"abstract":"<p>Novel PVC membrane electrodes for the determination of betaine ion based on the formation of betaine-tetraphenylborate (Be-TPB) and betaine-phosphotungstate (Be-PT) ion-exchangers as electroactive materials are described. The sensors show a fast, stable, near Nernstian response for 6.92 × 10<sup>-6</sup> to 7.94 × 10<sup>-3</sup> M and 1.0 × 10<sup>-4</sup> to 1.0 × 10<sup>-2</sup> M betaine hydrochloride (Be.Cl) in case of Be-TPB electrode applying batch and flow injection analysis (FIA), respectively, and 2.95 × 10<sup>-5</sup> to 2.26 × 10<sup>-3</sup> M and 3.16 × 10<sup>-5</sup> to 1.0 × 10<sup>-2</sup> M in case of Be-PT electrode for batch and FIA electrodes, respectively, at 25 °C over the pH range of 3.5-10 with a cationic slope of 60.2 and 59.1 mV decade<sup>-1</sup> and a fast potential response of ≤ 15 s. The lower detection limits are 7.94 × 10<sup>-6</sup> and 3.18 × 10<sup>-5</sup> M Be.Cl for Be-TPB and Be-PT electrodes, respectively. Selectivity coefficient data for some common inorganic cations, sugars, amino acids and the components other than betaine, of the mixed drug investigated show negligible interference. The electrodes have been applied to the direct potentiometric determination of betaine hydrochloride in water and in a pharmaceutical preparation under batch and FIA conditions. Potentiometric titrations of Be.Cl with NaTPB and PTA as titrants were monitored with the developed betaine electrodes as an end point indicator electrode. The determination of Be.Cl shows an average recovery of 100.8 % with mean relative standard deviation of 0.61 %. The effect of temperature on the electrodes was also studied.</p>","PeriodicalId":8193,"journal":{"name":"Annali di chimica","volume":"97 3-4","pages":"213-225"},"PeriodicalIF":0.0000,"publicationDate":"2007-02-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1002/adic.200790006","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annali di chimica","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/adic.200790006","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Novel PVC membrane electrodes for the determination of betaine ion based on the formation of betaine-tetraphenylborate (Be-TPB) and betaine-phosphotungstate (Be-PT) ion-exchangers as electroactive materials are described. The sensors show a fast, stable, near Nernstian response for 6.92 × 10-6 to 7.94 × 10-3 M and 1.0 × 10-4 to 1.0 × 10-2 M betaine hydrochloride (Be.Cl) in case of Be-TPB electrode applying batch and flow injection analysis (FIA), respectively, and 2.95 × 10-5 to 2.26 × 10-3 M and 3.16 × 10-5 to 1.0 × 10-2 M in case of Be-PT electrode for batch and FIA electrodes, respectively, at 25 °C over the pH range of 3.5-10 with a cationic slope of 60.2 and 59.1 mV decade-1 and a fast potential response of ≤ 15 s. The lower detection limits are 7.94 × 10-6 and 3.18 × 10-5 M Be.Cl for Be-TPB and Be-PT electrodes, respectively. Selectivity coefficient data for some common inorganic cations, sugars, amino acids and the components other than betaine, of the mixed drug investigated show negligible interference. The electrodes have been applied to the direct potentiometric determination of betaine hydrochloride in water and in a pharmaceutical preparation under batch and FIA conditions. Potentiometric titrations of Be.Cl with NaTPB and PTA as titrants were monitored with the developed betaine electrodes as an end point indicator electrode. The determination of Be.Cl shows an average recovery of 100.8 % with mean relative standard deviation of 0.61 %. The effect of temperature on the electrodes was also studied.

盐酸甜菜碱的间歇和流动注射电位分析
介绍了以甜菜碱四苯基硼酸盐(Be-TPB)和甜菜碱磷钨酸盐(Be-PT)离子交换剂为电活性材料的新型PVC膜电极测定甜菜碱离子。Be-TPB电极对6.92 × 10-6 ~ 7.94 × 10-3 M和1.0 × 10-4 ~ 1.0 × 10-2 M盐酸甜菜碱(Be.Cl)的响应快速稳定,Be-PT电极对2.95 × 10-5 ~ 2.26 × 10-3 M和3.16 × 10-5 ~ 1.0 × 10-2 M的响应快速稳定,分别适用于批量和流动注射分析(FIA)。在25°C下,pH范围为3.5-10,阳离子斜率为60.2和59.1 mV decade-1,电位响应速度≤15 s。下检出限分别为7.94 × 10-6和3.18 × 10-5 M Be。Cl分别用于Be-TPB和Be-PT电极。混合药物中常见的无机阳离子、糖、氨基酸和甜菜碱以外的组分的选择性系数数据显示干扰可以忽略不计。该电极已应用于在批处理和FIA条件下直接电位法测定水中和药物制剂中的盐酸甜菜碱。Be的电位滴定法。用研制的甜菜碱电极作为终点指示电极,对以NaTPB和PTA为滴定剂的氯离子进行监测。Be的测定。Cl的平均回收率为100.8%,平均相对标准偏差为0.61%。研究了温度对电极的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信