[Studies for analyzing restricted ingredients such as phenylbenzoimidazole sulfonic acid].

Q4 Medicine
Hiroshi Tokunaga, Kenichiro Mori, Nahomi Onuki, Tomio Nosaka, Kayo Doi, Hiroshi Sakaguchi, Makiko Fujii, Katuhiro Takano, Masato Hayashi, Kenichi Yoshizawa, Kimio Shimamura, Nobuo Sato
{"title":"[Studies for analyzing restricted ingredients such as phenylbenzoimidazole sulfonic acid].","authors":"Hiroshi Tokunaga,&nbsp;Kenichiro Mori,&nbsp;Nahomi Onuki,&nbsp;Tomio Nosaka,&nbsp;Kayo Doi,&nbsp;Hiroshi Sakaguchi,&nbsp;Makiko Fujii,&nbsp;Katuhiro Takano,&nbsp;Masato Hayashi,&nbsp;Kenichi Yoshizawa,&nbsp;Kimio Shimamura,&nbsp;Nobuo Sato","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Phenylbenzoimidazol sulfonic acid (PBS) is a kind of sunscreens in cosmetics and is nominated as the restricted ingredients in cosmetics in Japanese Pharmaceutical Affairs Act. So the analytical method for PBS was investigated by HPLC. 1.0 g of the lotions with 1.0% PBS was exactly weighed, put into a 50-mL volumetric flask. Water was added to make exactly 50 mL and this mixture was used as the sample solution. On the other hand, 1.0 g of the creams with 1.0% PBS was exactly weighed, put into a beaker. After adding 1 mL of tetrahydrofuran and dissolving the cream, that mixture was transferred to a 50-mL volumetric flask. And then the beaker was rinsed with 1 mL of tetrahydrofuran and the rinsed solution was put together into the volumetric flask. After adding water to the volumetric flask to make exactly 50 mL, this mixture was used as the sample solution. If necessary, the mixture was filtrated with a membrane filter (0.45 microm). 5.0 mL of the sample solution was pipetted and put into a 200-mL volumetric flask. After adding water to make exactly 200 mL, 20 microL of this solution was analyzed by HPLC using the ODS column (CAPCELL PAK C18 column, 4.6 mm i.d. x 250 mm), the mixture of 40 mmol/L acetic buffer (pH 3.4) and acetonitrile (3:1) with 0.8 mmol/L dodecyltrimethyl ammonium bromide and the detection wavelength of 305 nm. The working curve from 0.5 to 20.0 microg/mL showed a linear line between the concentrations of PBS and the peak areas. There was no interference of peak of PBS from the lotion and cream.</p>","PeriodicalId":35462,"journal":{"name":"Bulletin of National Institute of Health Sciences","volume":" 124","pages":"38-42"},"PeriodicalIF":0.0000,"publicationDate":"2006-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bulletin of National Institute of Health Sciences","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Phenylbenzoimidazol sulfonic acid (PBS) is a kind of sunscreens in cosmetics and is nominated as the restricted ingredients in cosmetics in Japanese Pharmaceutical Affairs Act. So the analytical method for PBS was investigated by HPLC. 1.0 g of the lotions with 1.0% PBS was exactly weighed, put into a 50-mL volumetric flask. Water was added to make exactly 50 mL and this mixture was used as the sample solution. On the other hand, 1.0 g of the creams with 1.0% PBS was exactly weighed, put into a beaker. After adding 1 mL of tetrahydrofuran and dissolving the cream, that mixture was transferred to a 50-mL volumetric flask. And then the beaker was rinsed with 1 mL of tetrahydrofuran and the rinsed solution was put together into the volumetric flask. After adding water to the volumetric flask to make exactly 50 mL, this mixture was used as the sample solution. If necessary, the mixture was filtrated with a membrane filter (0.45 microm). 5.0 mL of the sample solution was pipetted and put into a 200-mL volumetric flask. After adding water to make exactly 200 mL, 20 microL of this solution was analyzed by HPLC using the ODS column (CAPCELL PAK C18 column, 4.6 mm i.d. x 250 mm), the mixture of 40 mmol/L acetic buffer (pH 3.4) and acetonitrile (3:1) with 0.8 mmol/L dodecyltrimethyl ammonium bromide and the detection wavelength of 305 nm. The working curve from 0.5 to 20.0 microg/mL showed a linear line between the concentrations of PBS and the peak areas. There was no interference of peak of PBS from the lotion and cream.

[苯并咪唑磺酸等限用成分分析研究]。
苯并咪唑磺酸(PBS)是化妆品中的一种防晒剂,在日本药事法中被指定为化妆品中的限用成分。为此,研究了高效液相色谱法测定PBS的方法。准确称取1.0 g含1.0% PBS的洗液,放入50ml容量瓶中。水加到50毫升,这个混合物用作样品溶液。另一方面,将1.0 g含有1.0% PBS的乳霜精确称重,放入烧杯中。加入1ml四氢呋喃并溶解乳膏后,将混合物转移到50ml的容量瓶中。然后用1ml的四氢呋喃冲洗烧杯,冲洗后的溶液一起放入量瓶中。在体积瓶中加水至50ml后,将此混合物用作样品溶液。必要时,用0.45微米的膜过滤器过滤混合物。移液取5.0 mL样品溶液,放入200 mL容量瓶中。加水至200 mL,取该溶液20 μ L,采用高效液相色谱法分析,色谱柱为ODS柱(CAPCELL PAK C18柱,4.6 mm id × 250 mm), 40 mmol/L乙酸缓冲液(pH 3.4)与乙腈(3:1)与0.8 mmol/L十二烷基三甲基溴化铵混合,检测波长为305 nm。在0.5 ~ 20.0 μ g/mL范围内,PBS浓度与峰面积呈线性关系。洗剂和面霜对PBS峰值无干扰。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
0.20
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信