Evaluation of exposure to methyl methacrylate among dental laboratory technicians.

A Nayebzadeh, A Dufresne
{"title":"Evaluation of exposure to methyl methacrylate among dental laboratory technicians.","authors":"A Nayebzadeh,&nbsp;A Dufresne","doi":"10.1080/00028899908984482","DOIUrl":null,"url":null,"abstract":"<p><p>Following the diagnosis of two cases of occupational asthma among dental technicians, an industrial hygiene survey was conducted in two dental laboratories to determine time-weighted average and peak concentrations of methyl methacrylate vapor and time-weighted average concentration of acrylic dust. The time-weighted average concentrations of methyl methacrylate vapor were 0.7 ppm and 1.6 ppm and average peak concentrations were 9.3 ppm and 9.7 ppm for the first and second laboratory, respectively. The use of a local exhaust ventilation system was significant in reducing the peak concentration of methyl methacrylate vapor in the breathing zone of dental technicians. However, the local exhaust ventilation was not efficient in reducing the concentration of airborne acrylic dusts. Occupational exposure of dental technicians to dental materials, in particular to methyl methacrylate, requires further investigation. Local exhaust ventilation systems can reduce the concentration of methyl methacrylate in the dental laboratories to a significant extent if installed and used properly.</p>","PeriodicalId":7930,"journal":{"name":"American Industrial Hygiene Association journal","volume":"60 5","pages":"625-8"},"PeriodicalIF":0.0000,"publicationDate":"1999-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1080/00028899908984482","citationCount":"28","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"American Industrial Hygiene Association journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/00028899908984482","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 28

Abstract

Following the diagnosis of two cases of occupational asthma among dental technicians, an industrial hygiene survey was conducted in two dental laboratories to determine time-weighted average and peak concentrations of methyl methacrylate vapor and time-weighted average concentration of acrylic dust. The time-weighted average concentrations of methyl methacrylate vapor were 0.7 ppm and 1.6 ppm and average peak concentrations were 9.3 ppm and 9.7 ppm for the first and second laboratory, respectively. The use of a local exhaust ventilation system was significant in reducing the peak concentration of methyl methacrylate vapor in the breathing zone of dental technicians. However, the local exhaust ventilation was not efficient in reducing the concentration of airborne acrylic dusts. Occupational exposure of dental technicians to dental materials, in particular to methyl methacrylate, requires further investigation. Local exhaust ventilation systems can reduce the concentration of methyl methacrylate in the dental laboratories to a significant extent if installed and used properly.

牙科实验室技术人员甲基丙烯酸甲酯暴露的评估。
在诊断了2例牙科技师职业性哮喘后,对2个牙科实验室进行了工业卫生调查,测定了甲基丙烯酸甲酯蒸气的时间加权平均浓度和峰值浓度以及丙烯酸粉尘的时间加权平均浓度。第一和第二实验室的甲基丙烯酸甲酯蒸汽的时间加权平均浓度分别为0.7 ppm和1.6 ppm,平均峰值浓度分别为9.3 ppm和9.7 ppm。局部排气通风系统的使用对降低牙科技术人员呼吸区甲基丙烯酸甲酯蒸汽的峰值浓度具有重要意义。然而,局部排气通风对降低空气中亚克力粉尘浓度效果不明显。牙科技术人员的职业暴露于牙科材料,特别是甲基丙烯酸甲酯,需要进一步调查。如果安装和使用得当,局部排气通风系统可以在很大程度上降低牙科实验室中甲基丙烯酸甲酯的浓度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信