Evaluation and design of a small portable EMG amplifier with potential RMS output.

Y Shimomura, K Iwanaga, H Harada, T Katsuura
{"title":"Evaluation and design of a small portable EMG amplifier with potential RMS output.","authors":"Y Shimomura,&nbsp;K Iwanaga,&nbsp;H Harada,&nbsp;T Katsuura","doi":"10.2114/jpa.18.61","DOIUrl":null,"url":null,"abstract":"<p><p>The present study attempted to design and evaluate a small portable electromyogram (EMG) amplifier that can output enhanced EMG and its root mean square (RMS) value. The production and design were of a laboratory scale without any special or high cost circuit construction. The designed amplifier was actually innovated according to the actual working conditions based on physiological anthropology. The present amplifier was compared with commercially available products and proved to be of practical use. The device was installed with a sufficiently small body depicting 8-channel variable gain AC amplifier and variable time-window RMS-to-DC converter. The prototype was battery-driven and well-shielded to minimize external noise interference.</p>","PeriodicalId":79317,"journal":{"name":"Applied human science : journal of physiological anthropology","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1999-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.2114/jpa.18.61","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Applied human science : journal of physiological anthropology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2114/jpa.18.61","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

Abstract

The present study attempted to design and evaluate a small portable electromyogram (EMG) amplifier that can output enhanced EMG and its root mean square (RMS) value. The production and design were of a laboratory scale without any special or high cost circuit construction. The designed amplifier was actually innovated according to the actual working conditions based on physiological anthropology. The present amplifier was compared with commercially available products and proved to be of practical use. The device was installed with a sufficiently small body depicting 8-channel variable gain AC amplifier and variable time-window RMS-to-DC converter. The prototype was battery-driven and well-shielded to minimize external noise interference.

具有电位均方根输出的小型便携式肌电放大器的评估与设计。
本研究试图设计和评估一种小型便携式肌电信号放大器,该放大器可以输出增强的肌电信号及其均方根值。生产和设计是实验室规模,没有任何特殊的或高成本的电路建设。在生理人类学的基础上,根据实际工况对所设计的放大器进行了创新。与市售产品进行了比较,证明了该放大器的实用性。该装置安装了一个足够小的机身,描绘了8通道可变增益交流放大器和可变时窗RMS-to-DC转换器。原型机由电池驱动,屏蔽良好,最大限度地减少外部噪音干扰。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信