Preventing abortion and repeat abortion with the Gynefix intrauterine implant system--preliminary results.

I Batar, D Wildemeersch, M Vrijens, W Delbarge, M Temmerman, B A Gbolade
{"title":"Preventing abortion and repeat abortion with the Gynefix intrauterine implant system--preliminary results.","authors":"I Batar,&nbsp;D Wildemeersch,&nbsp;M Vrijens,&nbsp;W Delbarge,&nbsp;M Temmerman,&nbsp;B A Gbolade","doi":"10.1023/a:1006582515744","DOIUrl":null,"url":null,"abstract":"<p><p>The provision of immediate post-abortal contraception is important to reduce the number of unplanned pregnancies and the number of repeat abortions. Immediate post-abortal insertion of an IUD has many advantages and is an acceptable and safe method. However, side-effects and expulsion of conventional IUDs remain a problem. In an attempt to minimize these problems, the frameless intrauterine implant (IUI) was developed. Clinical studies conducted over the past 12 years have shown the validity of the anchoring concept. The design characteristics of the IUI (fixed, frameless and flexible) are responsible for the low expulsion, high effectiveness and high tolerance rates. This communication is the first report of clinical experience with the post-abortal version of Gynefix (Gynefix PT) in a limited number of women with pregnancies of less than 10 weeks' duration. This experience suggests that immediate post-abortal insertion of Gynefix PT is easy, safe and the implant appears to be as reliable and effective as interval insertion of the interval version. We conclude that the immediate post-abortal insertion of Gynefix PT is an important novel approach to reducing the incidence of repeat abortions.</p>","PeriodicalId":76977,"journal":{"name":"Advances in contraception : the official journal of the Society for the Advancement of Contraception","volume":"14 2","pages":"91-6"},"PeriodicalIF":0.0000,"publicationDate":"1998-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1023/a:1006582515744","citationCount":"16","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advances in contraception : the official journal of the Society for the Advancement of Contraception","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1023/a:1006582515744","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 16

Abstract

The provision of immediate post-abortal contraception is important to reduce the number of unplanned pregnancies and the number of repeat abortions. Immediate post-abortal insertion of an IUD has many advantages and is an acceptable and safe method. However, side-effects and expulsion of conventional IUDs remain a problem. In an attempt to minimize these problems, the frameless intrauterine implant (IUI) was developed. Clinical studies conducted over the past 12 years have shown the validity of the anchoring concept. The design characteristics of the IUI (fixed, frameless and flexible) are responsible for the low expulsion, high effectiveness and high tolerance rates. This communication is the first report of clinical experience with the post-abortal version of Gynefix (Gynefix PT) in a limited number of women with pregnancies of less than 10 weeks' duration. This experience suggests that immediate post-abortal insertion of Gynefix PT is easy, safe and the implant appears to be as reliable and effective as interval insertion of the interval version. We conclude that the immediate post-abortal insertion of Gynefix PT is an important novel approach to reducing the incidence of repeat abortions.

Gynefix宫内植入系统预防流产和重复流产——初步结果。
立即提供流产后避孕对于减少计划外怀孕和重复流产的数量非常重要。流产后立即插入宫内节育器有许多优点,是一种可接受和安全的方法。然而,传统宫内节育器的副作用和排出仍然是一个问题。为了尽量减少这些问题,无框宫内植入物(IUI)被开发出来。过去12年进行的临床研究表明了锚定概念的有效性。IUI的设计特点(固定、无框、灵活)是低排烟、高效率和高容差率的原因。本报告是第一份使用流产后版Gynefix (Gynefix PT)治疗妊娠期少于10周的有限女性的临床经验报告。这一经验表明,流产后即刻植入Gynefix PT是简单、安全的,植入物与间隔植入一样可靠和有效。我们得出结论,即刻流产后插入Gynefix PT是减少重复流产发生率的重要新方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信