{"title":"Quantitative analysis of x-ray images with a television image analyser.","authors":"A Schleicher, B Tillmann, K Zilles","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>A method for the quantitative evaluation of X-rays is described. The image is decomposed into individual image points by a mechanical scanning procedure, and at each image point the area fraction of a measuring field not covered by silver grains is determined with an image analyzer. This parameter is interpreted as representing a value corresponding to a specific degree of film blackness. The relationship between the measured value and the X-ray absorption is described by standard curves. With the aid of an aluminum scale, the measured value can be expressed directly by the thickness of an aluminum equivalent with a corresponding X-ray absorption. Details about the adjustment of the image analyzer for detecting the silver grains, the resolution of different degrees of X-ray absorption, as well as the computer-controlled scanning procedure are described. An example demonstrates its applicability to analyze the density distribution of bony tissue around the human humero-ulnar joint. The procedure is not limited to the evaluation of X-rays, but is applicable whenever silver grains can be detected in a film layer by an image analyzer.</p>","PeriodicalId":76158,"journal":{"name":"Microscopica acta","volume":"83 3","pages":"189-96"},"PeriodicalIF":0.0000,"publicationDate":"1980-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Microscopica acta","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
A method for the quantitative evaluation of X-rays is described. The image is decomposed into individual image points by a mechanical scanning procedure, and at each image point the area fraction of a measuring field not covered by silver grains is determined with an image analyzer. This parameter is interpreted as representing a value corresponding to a specific degree of film blackness. The relationship between the measured value and the X-ray absorption is described by standard curves. With the aid of an aluminum scale, the measured value can be expressed directly by the thickness of an aluminum equivalent with a corresponding X-ray absorption. Details about the adjustment of the image analyzer for detecting the silver grains, the resolution of different degrees of X-ray absorption, as well as the computer-controlled scanning procedure are described. An example demonstrates its applicability to analyze the density distribution of bony tissue around the human humero-ulnar joint. The procedure is not limited to the evaluation of X-rays, but is applicable whenever silver grains can be detected in a film layer by an image analyzer.