Patency of heparinized SBS shunts at high shear rates.

M V Sefton, W Zingg
{"title":"Patency of heparinized SBS shunts at high shear rates.","authors":"M V Sefton,&nbsp;W Zingg","doi":"10.3109/10731198109118994","DOIUrl":null,"url":null,"abstract":"<p><p>The patency of 50 cm long, 1.7 mm ID heparin-polyvinyl alcohol (PVA) coated SBS arterio-venous shunts in pigs at shear rates greater than 1000 s-1 was found to be not different from that of identical shunts coated with PVA but without heparin. This was attributed to the absence of any measureable effect of surface bound heparin on platelet related thrombus formation at high shear rates. On the other hand, platelet adhesion values determined in the absence of flow by the open static method decreased with increasing heparin content in heparin-PVA films. The low overall patency (average life of 170 minutes) of the PVA coated SBS shunts (with and without heparin) was presumed to be related to the absence of circulating heparin during surgery and the consequent presence of tissue thromboplastin or cellular debris during the immediate postoperative period. Alternative protocols are needed to test heparinized materials at low shear rates in the absence of systemic heparin to properly assess the potential thrombo-resistance of such materials.</p>","PeriodicalId":75597,"journal":{"name":"Biomaterials, medical devices, and artificial organs","volume":"9 2","pages":"127-42"},"PeriodicalIF":0.0000,"publicationDate":"1981-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3109/10731198109118994","citationCount":"11","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomaterials, medical devices, and artificial organs","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3109/10731198109118994","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 11

Abstract

The patency of 50 cm long, 1.7 mm ID heparin-polyvinyl alcohol (PVA) coated SBS arterio-venous shunts in pigs at shear rates greater than 1000 s-1 was found to be not different from that of identical shunts coated with PVA but without heparin. This was attributed to the absence of any measureable effect of surface bound heparin on platelet related thrombus formation at high shear rates. On the other hand, platelet adhesion values determined in the absence of flow by the open static method decreased with increasing heparin content in heparin-PVA films. The low overall patency (average life of 170 minutes) of the PVA coated SBS shunts (with and without heparin) was presumed to be related to the absence of circulating heparin during surgery and the consequent presence of tissue thromboplastin or cellular debris during the immediate postoperative period. Alternative protocols are needed to test heparinized materials at low shear rates in the absence of systemic heparin to properly assess the potential thrombo-resistance of such materials.

高剪切率下肝素化SBS分流的通畅。
在剪切速率大于1000 s-1的情况下,长50 cm、直径1.7 mm的肝素-聚乙烯醇(PVA)包被SBS动静脉分流器的通畅程度与包被PVA但不包被肝素的相同分流器的通畅程度无显著差异。这是由于在高剪切速率下,表面结合肝素对血小板相关血栓形成没有任何可测量的影响。另一方面,在无流动条件下,开放静态法测定的血小板粘附值随着肝素- pva膜中肝素含量的增加而降低。PVA涂层SBS分流术(含或不含肝素)的总通畅度低(平均寿命为170分钟)被认为与手术期间循环肝素的缺乏以及随后在术后立即出现组织凝血活素或细胞碎片有关。在缺乏全体性肝素的情况下,需要替代方案在低剪切速率下测试肝素化材料,以正确评估此类材料的潜在血栓抵抗性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信