{"title":"[Thermoresistance of Legionella].","authors":"J F Hernandez, J M Delattre, C Oger","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Cells of Legionella suspended in water were heated for 15 to 60 min, at temperatures between 40 and 70 degrees C, and their survival determined over 9 log-cycles. The survival curves were identical for the 6 strains, and were non-logarithmic. Implications of the resistance plateau observed are discussed.</p>","PeriodicalId":7904,"journal":{"name":"Annales de microbiologie","volume":"134B 3","pages":"421-7"},"PeriodicalIF":0.0000,"publicationDate":"1983-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annales de microbiologie","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Cells of Legionella suspended in water were heated for 15 to 60 min, at temperatures between 40 and 70 degrees C, and their survival determined over 9 log-cycles. The survival curves were identical for the 6 strains, and were non-logarithmic. Implications of the resistance plateau observed are discussed.