Comparison between homogeneous phase radioassay and enzyme-linked immunosorbent assay for measurement of antithyroglobulin antibody content in serum. Relation to presence of thyroglobulin.

U Feldt-Rasmussen, M Høier-Madsen, H S Hansen, M Blichert-Toft
{"title":"Comparison between homogeneous phase radioassay and enzyme-linked immunosorbent assay for measurement of antithyroglobulin antibody content in serum. Relation to presence of thyroglobulin.","authors":"U Feldt-Rasmussen,&nbsp;M Høier-Madsen,&nbsp;H S Hansen,&nbsp;M Blichert-Toft","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The aim of the study was to test the influence of thyroglobulin in vitro and in vivo on two different principles for quantification of serum antithyroglobulin antibody content. The methods employed were a previously described homogeneous phase radioassay and a newly developed enzyme-linked immunosorbent assay. Thyroglobulin inhibited the measurement of antithyroglobulin antibody content by both methods, not only by addition in vitro but also when present in vivo as a result of release from thyroid surgery. Both methods proved sufficiently sensitive as screening for presence of antithyroglobulin antibodies before measurement of thyroglobulin in serum. The study shows the importance of assessing the assay systems in each laboratory for interference before use, especially if intended for screening before quantifying serum thyroglobulin or for measurement of antithyroglobulin antibodies in other media (e.g. supernatants from lymphocyte cultures).</p>","PeriodicalId":77653,"journal":{"name":"Acta pathologica, microbiologica, et immunologica Scandinavica. Section C, Immunology","volume":"94 1","pages":"33-8"},"PeriodicalIF":0.0000,"publicationDate":"1986-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta pathologica, microbiologica, et immunologica Scandinavica. Section C, Immunology","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The aim of the study was to test the influence of thyroglobulin in vitro and in vivo on two different principles for quantification of serum antithyroglobulin antibody content. The methods employed were a previously described homogeneous phase radioassay and a newly developed enzyme-linked immunosorbent assay. Thyroglobulin inhibited the measurement of antithyroglobulin antibody content by both methods, not only by addition in vitro but also when present in vivo as a result of release from thyroid surgery. Both methods proved sufficiently sensitive as screening for presence of antithyroglobulin antibodies before measurement of thyroglobulin in serum. The study shows the importance of assessing the assay systems in each laboratory for interference before use, especially if intended for screening before quantifying serum thyroglobulin or for measurement of antithyroglobulin antibodies in other media (e.g. supernatants from lymphocyte cultures).

均相放射法与酶联免疫吸附法测定血清中抗甲状腺球蛋白含量的比较。与甲状腺球蛋白的存在有关。
本研究的目的是在体外和体内测试甲状腺球蛋白对两种不同原理的血清抗甲状腺球蛋白抗体含量的影响。采用的方法是先前描述的均相放射测定法和新开发的酶联免疫吸附测定法。甲状腺球蛋白抑制两种方法的抗甲状腺球蛋白抗体含量测定,不仅通过体外添加,而且由于甲状腺手术释放而存在于体内。这两种方法在测定血清中甲状腺球蛋白之前,对抗甲状腺球蛋白抗体的存在有足够的敏感性。该研究显示了在使用前评估每个实验室检测系统的干扰的重要性,特别是如果用于定量血清甲状腺球蛋白之前的筛选或用于测量其他介质(例如淋巴细胞培养的上清)中的抗甲状腺球蛋白抗体。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信