Protective value of powered dust respirator helmet for farmers with farmer's lung.

J Nuutinen, E O Terho, K Husman, M Kotimaa, R Härkönen, H Nousiainen
{"title":"Protective value of powered dust respirator helmet for farmers with farmer's lung.","authors":"J Nuutinen,&nbsp;E O Terho,&nbsp;K Husman,&nbsp;M Kotimaa,&nbsp;R Härkönen,&nbsp;H Nousiainen","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Seventeen victims of farmer's lung were monitored during two indoor feeding seasons for cattle. The victims, who had all recovered from the acute phase of the disease before entering the experiment, used powered helmets for respiratory protection (Air-Stream) equipped with Type P2 filters. Filters were changed once a week. The lung function of each subject was investigated at the beginning and towards the end of the indoor feeding season. Each subject kept a diary about the use of dust respirators, changing of filters, inconvenience related to the use of respirators, and symptoms experienced during the follow-up. None of the subjects reported symptoms they related to farmer's lung, and mean values for the lung function parameters (PEF, FEV1, FVC, DLCO, and KCO) did not decrease during the two follow-up periods. In contrast, mean DLCO and KCO increased slightly. At the very end of the both indoor feeding seasons, after the actual follow-up periods, one subject developed mild recurrences of the disease without deterioration detectable by radiology. The patient asserted that he had used the protective helmet properly. The results indicate that powered respirator helmets have protective value in farmer's lung and are appropriate for long-term use. A possibility remains, however, that the disease may recur in highly sensitized individuals, despite the use of efficient protective devices. Other measures for preventing or decreasing mould exposure are equally important.</p>","PeriodicalId":12048,"journal":{"name":"European journal of respiratory diseases. Supplement","volume":"152 ","pages":"212-20"},"PeriodicalIF":0.0000,"publicationDate":"1987-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European journal of respiratory diseases. Supplement","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Seventeen victims of farmer's lung were monitored during two indoor feeding seasons for cattle. The victims, who had all recovered from the acute phase of the disease before entering the experiment, used powered helmets for respiratory protection (Air-Stream) equipped with Type P2 filters. Filters were changed once a week. The lung function of each subject was investigated at the beginning and towards the end of the indoor feeding season. Each subject kept a diary about the use of dust respirators, changing of filters, inconvenience related to the use of respirators, and symptoms experienced during the follow-up. None of the subjects reported symptoms they related to farmer's lung, and mean values for the lung function parameters (PEF, FEV1, FVC, DLCO, and KCO) did not decrease during the two follow-up periods. In contrast, mean DLCO and KCO increased slightly. At the very end of the both indoor feeding seasons, after the actual follow-up periods, one subject developed mild recurrences of the disease without deterioration detectable by radiology. The patient asserted that he had used the protective helmet properly. The results indicate that powered respirator helmets have protective value in farmer's lung and are appropriate for long-term use. A possibility remains, however, that the disease may recur in highly sensitized individuals, despite the use of efficient protective devices. Other measures for preventing or decreasing mould exposure are equally important.

电动防尘头盔对农民肺的防护价值。
在两个室内饲养季节对17名农民肺受害者进行了监测。这些患者在进入实验前都已从急性期康复,他们使用了配有P2型过滤器的呼吸保护动力头盔(Air-Stream)。过滤器每周更换一次。分别在室内饲养季开始和结束时对各试验对象进行肺功能测定。每位受试者都记录了使用防尘呼吸器、更换过滤器、使用呼吸器带来的不便以及随访期间出现的症状。所有受试者均未报告与农民肺相关的症状,在两个随访期间,肺功能参数(PEF、FEV1、FVC、DLCO和KCO)的平均值没有下降。相比之下,平均DLCO和KCO略有增加。在两个室内喂养季节即将结束时,在实际随访期之后,一名受试者的疾病出现轻度复发,但放射学检测不到病情恶化。病人声称他正确地使用了防护头盔。结果表明,动力式呼吸帽对农民肺部有一定的保护作用,适合长期使用。然而,尽管使用了有效的保护装置,这种疾病仍有可能在高度敏感的个体中复发。其他预防或减少霉菌暴露的措施也同样重要。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信