In situ oxygen transmissibility of rigid gas-permeable contact lenses.

B A Weissman, I Fatt
{"title":"In situ oxygen transmissibility of rigid gas-permeable contact lenses.","authors":"B A Weissman,&nbsp;I Fatt","doi":"10.1097/00006324-198805000-00016","DOIUrl":null,"url":null,"abstract":"<p><p>On the eye a contact lens is bathed in tear fluid, which increases its resistance to oxygen flux. For rigid gas-permeable lenses, this effect should be small during open-eye wear because a large amount of oxygen is provided by air-saturated tears that are pumped under the lens. However, under closed-eye conditions this study suggests substantial decrease in overall lens system oxygen transmissibility when lens transmissibility itself is greater than 20 x 10(-9) cm ml O2/s ml mm Hg and when the average thickness of the tear layer is greater than about 20 micron.</p>","PeriodicalId":7700,"journal":{"name":"American journal of optometry and physiological optics","volume":"65 5","pages":"400-2"},"PeriodicalIF":0.0000,"publicationDate":"1988-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1097/00006324-198805000-00016","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"American journal of optometry and physiological optics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1097/00006324-198805000-00016","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

On the eye a contact lens is bathed in tear fluid, which increases its resistance to oxygen flux. For rigid gas-permeable lenses, this effect should be small during open-eye wear because a large amount of oxygen is provided by air-saturated tears that are pumped under the lens. However, under closed-eye conditions this study suggests substantial decrease in overall lens system oxygen transmissibility when lens transmissibility itself is greater than 20 x 10(-9) cm ml O2/s ml mm Hg and when the average thickness of the tear layer is greater than about 20 micron.

硬质透气性隐形眼镜的原位氧透射率。
在眼睛上,隐形眼镜浸泡在泪液中,这增加了它对氧气通量的抵抗力。对于刚性透气性镜片,这种影响在睁眼佩戴时应该很小,因为大量的氧气是由泵入镜片下的空气饱和泪液提供的。然而,在闭眼条件下,本研究表明,当晶状体本身的透氧率大于20 × 10(-9) cm ml O2/s ml mm Hg且泪液层的平均厚度大于约20微米时,晶状体系统的整体透氧率会大幅下降。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信