2025 International Expert Practical Guide on the Use of the Pentaspline Pulsed Field Ablation System in Atrial Fibrillation Ablation Procedures.

IF 9.8 1区 医学 Q1 CARDIAC & CARDIOVASCULAR SYSTEMS
Shaojie Chen, Sanjiv M Narayan, Serge Boveda, Kars Neven, Martin H Ruwald, Martin Martinek, Piotr Futyma, Christian Meyer, Christian-Hendrik Heeger, Philipp Sommer, Alexandra Schratter, Bart A Mulder, Márcio Galindo Kiuchi, Pipin Kojodjojo, Jeremy Chow, Mark T K Tam, Zhijun Sun, Jingquan Zhong, Yuehui Yin, Boris Schmidt, Julian K R Chun, Minglong Chen, Helmut Pürerfellner
{"title":"2025 International Expert Practical Guide on the Use of the Pentaspline Pulsed Field Ablation System in Atrial Fibrillation Ablation Procedures.","authors":"Shaojie Chen, Sanjiv M Narayan, Serge Boveda, Kars Neven, Martin H Ruwald, Martin Martinek, Piotr Futyma, Christian Meyer, Christian-Hendrik Heeger, Philipp Sommer, Alexandra Schratter, Bart A Mulder, Márcio Galindo Kiuchi, Pipin Kojodjojo, Jeremy Chow, Mark T K Tam, Zhijun Sun, Jingquan Zhong, Yuehui Yin, Boris Schmidt, Julian K R Chun, Minglong Chen, Helmut Pürerfellner","doi":"10.1161/CIRCEP.125.013977","DOIUrl":null,"url":null,"abstract":"<p><p>Pulsed field ablation (PFA) has been developed as a largely nonthermal ablation technology with a unique biophysical profile to treat atrial fibrillation. Existing evidence has shown that PFA offers a safe and efficient atrial fibrillation ablation procedure. Among different PFA technologies, the pentaspline FARAPULSE system has been the most extensively used and investigated; however, notable variability exists in workflow, fluoroscopy time, and lesion durability. While innovations such as 3-dimensional electroanatomic mapping systems and intracardiac echocardiography can enhance procedural precision in catheter ablation, fluoroscopy remains the primary imaging modality for guiding pentaspline PFA in many electrophysiology labs worldwide. This is particularly true in centers where limitations in cost, infrastructure, or training may preclude the routine use of advanced imaging technologies. This article summarizes general practical considerations and presents a primarily fluoroscopy-based, refined workflow developed by a group of experts. The goal is to provide a procedural foundation and practical guide for using the pentaspline FARAPULSE PFA system in atrial fibrillation ablation procedures. Developing a fluoroscopy-based practical guide would: (1) Democratize access to PFA technology, enabling safe and effective implementation across a broader range of clinical settings, including those without intracardiac echocardiography or 3-dimensional mapping support; (2) Reduce procedural heterogeneity by offering reproducible best practices; (3) Facilitate meaningful intercenter comparisons of procedural efficacy and safety, aiding in the identification of optimal approaches and improving the quality of clinical data for ongoing research, registries, and real-world performance monitoring of PFA technologies; and (4) Ultimately improve patient outcomes through standardized, accessible, and evidence-based practices.</p>","PeriodicalId":10319,"journal":{"name":"Circulation. Arrhythmia and electrophysiology","volume":" ","pages":"e013977"},"PeriodicalIF":9.8000,"publicationDate":"2025-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12533784/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Circulation. Arrhythmia and electrophysiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1161/CIRCEP.125.013977","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/7/31 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Pulsed field ablation (PFA) has been developed as a largely nonthermal ablation technology with a unique biophysical profile to treat atrial fibrillation. Existing evidence has shown that PFA offers a safe and efficient atrial fibrillation ablation procedure. Among different PFA technologies, the pentaspline FARAPULSE system has been the most extensively used and investigated; however, notable variability exists in workflow, fluoroscopy time, and lesion durability. While innovations such as 3-dimensional electroanatomic mapping systems and intracardiac echocardiography can enhance procedural precision in catheter ablation, fluoroscopy remains the primary imaging modality for guiding pentaspline PFA in many electrophysiology labs worldwide. This is particularly true in centers where limitations in cost, infrastructure, or training may preclude the routine use of advanced imaging technologies. This article summarizes general practical considerations and presents a primarily fluoroscopy-based, refined workflow developed by a group of experts. The goal is to provide a procedural foundation and practical guide for using the pentaspline FARAPULSE PFA system in atrial fibrillation ablation procedures. Developing a fluoroscopy-based practical guide would: (1) Democratize access to PFA technology, enabling safe and effective implementation across a broader range of clinical settings, including those without intracardiac echocardiography or 3-dimensional mapping support; (2) Reduce procedural heterogeneity by offering reproducible best practices; (3) Facilitate meaningful intercenter comparisons of procedural efficacy and safety, aiding in the identification of optimal approaches and improving the quality of clinical data for ongoing research, registries, and real-world performance monitoring of PFA technologies; and (4) Ultimately improve patient outcomes through standardized, accessible, and evidence-based practices.

2025关于在房颤消融手术中使用Pentaspline脉冲场消融系统的国际专家实用指南。
脉冲场消融(PFA)已经发展成为一种主要的非热消融技术,具有独特的生物物理特征来治疗心房颤动。现有证据表明PFA是一种安全有效的房颤消融方法。在不同的PFA技术中,五线FARAPULSE系统得到了最广泛的应用和研究;然而,在工作流程、透视时间和病变持久性方面存在显著差异。虽然诸如三维电解剖定位系统和心内超声心动图等创新技术可以提高导管消融的程序精度,但在全球许多电生理实验室中,透视仍然是指导pentaspline PFA的主要成像方式。在成本、基础设施或培训方面的限制可能妨碍常规使用先进成像技术的中心尤其如此。这篇文章总结了一般的实际考虑,并提出了一个主要的基于透视的,由一组专家开发的完善的工作流程。目的是为在房颤消融手术中使用pentaspline FARAPULSE PFA系统提供程序基础和实用指南。开发基于透视的实用指南将:(1)普及PFA技术,使其能够在更广泛的临床环境中安全有效地实施,包括那些没有心内超声心动图或三维绘图支持的临床环境;(2)通过提供可复制的最佳实践来减少程序异质性;(3)促进有意义的程序有效性和安全性的中心间比较,帮助确定最佳方法,提高正在进行的研究、注册和PFA技术实际性能监测的临床数据质量;(4)通过标准化、可获取和基于证据的实践最终改善患者的治疗效果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
13.70
自引率
4.80%
发文量
187
审稿时长
4-8 weeks
期刊介绍: Circulation: Arrhythmia and Electrophysiology is a journal dedicated to the study and application of clinical cardiac electrophysiology. It covers a wide range of topics including the diagnosis and treatment of cardiac arrhythmias, as well as research in this field. The journal accepts various types of studies, including observational research, clinical trials, epidemiological studies, and advancements in translational research.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信