Successful Ethanol Infusion of Vein of Marshall With Bridge Collateral Using the Double-Balloon Technique Incorporating a Wedged Berman Catheter

IF 1.7 Q2 CARDIAC & CARDIOVASCULAR SYSTEMS
Yuhei Kasai, Takayuki Kitai, Junji Morita, Kei Murakami, Tsutomu Fujita
{"title":"Successful Ethanol Infusion of Vein of Marshall With Bridge Collateral Using the Double-Balloon Technique Incorporating a Wedged Berman Catheter","authors":"Yuhei Kasai,&nbsp;Takayuki Kitai,&nbsp;Junji Morita,&nbsp;Kei Murakami,&nbsp;Tsutomu Fujita","doi":"10.1002/joa3.70152","DOIUrl":null,"url":null,"abstract":"<p>We describe a novel double-balloon technique incorporating a wedged Berman catheter to manage distal collateral drainage from the vein of Marshall (VOM) via a bridge collateral to the great cardiac vein, thereby enabling effective ethanol infusion. This technique may represent a viable alternative for anatomically challenging VOM ethanol infusion cases.\n <figure>\n <div><picture>\n <source></source></picture><p></p>\n </div>\n </figure></p>","PeriodicalId":15174,"journal":{"name":"Journal of Arrhythmia","volume":"41 4","pages":""},"PeriodicalIF":1.7000,"publicationDate":"2025-07-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1002/joa3.70152","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Arrhythmia","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/joa3.70152","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

We describe a novel double-balloon technique incorporating a wedged Berman catheter to manage distal collateral drainage from the vein of Marshall (VOM) via a bridge collateral to the great cardiac vein, thereby enabling effective ethanol infusion. This technique may represent a viable alternative for anatomically challenging VOM ethanol infusion cases.

Abstract Image

结合楔形伯曼导管的双球囊技术在桥侧静脉中成功的乙醇输注
我们描述了一种新的双球囊技术,结合楔形伯曼导管,通过桥式侧枝到心脏大静脉,来管理远侧支从马歇尔静脉(VOM)引流,从而实现有效的乙醇输注。这项技术可能是解剖学上具有挑战性的VOM乙醇输注病例的可行选择。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Arrhythmia
Journal of Arrhythmia CARDIAC & CARDIOVASCULAR SYSTEMS-
CiteScore
2.90
自引率
10.00%
发文量
127
审稿时长
45 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信