{"title":"Step-by-step reduction utilizing a one-third tubular plate in surgery for distal femur fracture with severe metaphyseal comminution: A case report","authors":"Kazuki Abe , Toru Iga","doi":"10.1016/j.tcr.2025.101226","DOIUrl":null,"url":null,"abstract":"<div><h3>Introduction</h3><div>Surgery for distal femur fractures with metaphyseal comminution remains challenging due to the multiplanar displacement, including the coronal and sagittal alignment, rotation, and length.</div></div><div><h3>Case presentation</h3><div>A 42-year-old male fell from a height and sustained a distal femur fracture with severe metaphyseal comminution. In surgery, a supplemental one-third tubular plate was placed medially for provisional fixation, enabling a sequential reduction for length, rotation, sagittal alignment, and coronal alignment. The fracture was finally stabilized with a lateral locking plate. The reduction parameters achieved and the functional outcome were satisfactory.</div></div><div><h3>Conclusion</h3><div>The one-third tubular plate simplified the reduction process by decomposing the multiplanar reduction into three dimensions and enabling a step-by-step approach.</div></div>","PeriodicalId":23291,"journal":{"name":"Trauma Case Reports","volume":"58 ","pages":"Article 101226"},"PeriodicalIF":0.0000,"publicationDate":"2025-07-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Trauma Case Reports","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2352644025001037","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0
Abstract
Introduction
Surgery for distal femur fractures with metaphyseal comminution remains challenging due to the multiplanar displacement, including the coronal and sagittal alignment, rotation, and length.
Case presentation
A 42-year-old male fell from a height and sustained a distal femur fracture with severe metaphyseal comminution. In surgery, a supplemental one-third tubular plate was placed medially for provisional fixation, enabling a sequential reduction for length, rotation, sagittal alignment, and coronal alignment. The fracture was finally stabilized with a lateral locking plate. The reduction parameters achieved and the functional outcome were satisfactory.
Conclusion
The one-third tubular plate simplified the reduction process by decomposing the multiplanar reduction into three dimensions and enabling a step-by-step approach.
期刊介绍:
Trauma Case Reports is the only open access, online journal dedicated to the publication of case reports in all aspects of trauma care and accident surgery. Case reports on all aspects of trauma management, surgical procedures for all tissues, resuscitation, anaesthesia and trauma and tissue healing will be considered for publication by the international editorial team and will be subject to peer review. Bringing together these cases from an international authorship will shed light on surgical problems and help in their effective resolution.