Analysis of a four-year experience with depth electrodes and a two-year experience with subdural electrodes in the evaluation of ablative seizure surgery candidates.

J R Smith, H F Flanigin, D W King, B B Gallagher, A M Murro, G L Holmes, K Huh
{"title":"Analysis of a four-year experience with depth electrodes and a two-year experience with subdural electrodes in the evaluation of ablative seizure surgery candidates.","authors":"J R Smith,&nbsp;H F Flanigin,&nbsp;D W King,&nbsp;B B Gallagher,&nbsp;A M Murro,&nbsp;G L Holmes,&nbsp;K Huh","doi":"10.1159/000100744","DOIUrl":null,"url":null,"abstract":"<p><p>Chronically implanted depth and subdural electrodes have both been shown to be satisfactory means of localizing epileptogenic foci. Utilizing bilateral mesial temporal depth electrodes, we have localized mesial temporal foci in a large percentage of patients. Depth electrode investigation of a more limited number of patients with suspected extramesial temporal foci has not been as reliable in giving localizing information. We have more recently used subdural electrodes to investigate this latter category of patients, and preliminary findings suggest that this technique may be of localizing value in several subcategories.</p>","PeriodicalId":75525,"journal":{"name":"Applied neurophysiology","volume":"50 1-6","pages":"380-5"},"PeriodicalIF":0.0000,"publicationDate":"1987-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1159/000100744","citationCount":"13","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Applied neurophysiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1159/000100744","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 13

Abstract

Chronically implanted depth and subdural electrodes have both been shown to be satisfactory means of localizing epileptogenic foci. Utilizing bilateral mesial temporal depth electrodes, we have localized mesial temporal foci in a large percentage of patients. Depth electrode investigation of a more limited number of patients with suspected extramesial temporal foci has not been as reliable in giving localizing information. We have more recently used subdural electrodes to investigate this latter category of patients, and preliminary findings suggest that this technique may be of localizing value in several subcategories.

分析四年的深度电极和两年的硬膜下电极在消融癫痫手术候选人评估中的经验。
长期植入深度电极和硬脑膜下电极都被证明是定位致痫灶的满意方法。利用双侧颞内侧深度电极,我们在很大比例的患者中定位了颞内侧病灶。深度电极调查更有限的患者怀疑颞外灶,并没有提供可靠的定位信息。我们最近使用硬膜下电极来研究后一类患者,初步发现表明该技术可能在几个亚类别中具有定位价值。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信