Miguel Ángel Nava Blanco, Gerardo Antonio Castañón Ávila
{"title":"Numerical Analysis of a SiN Digital Fourier Transform Spectrometer for a Non-Invasive Skin Cancer Biosensor.","authors":"Miguel Ángel Nava Blanco, Gerardo Antonio Castañón Ávila","doi":"10.3390/s25123792","DOIUrl":null,"url":null,"abstract":"<p><p>Early detection and continuous monitoring of diseases are critical to improving patient outcomes, treatment adherence, and diagnostic accuracy. Traditional melanoma diagnosis relies primarily on visual assessment and biopsy, with reported accuracies ranging from 50% to 90% and significant inter-observer variability. Among emerging diagnostic technologies, Raman spectroscopy has demonstrated considerable promise for non-invasive disease detection, particularly in early-stage skin cancer identification. A portable, real-time Raman spectroscopy system could significantly enhance diagnostic precision, reduce biopsy reliance, and expedite diagnosis. However, miniaturization of Raman spectrometers for portable use faces significant challenges, including weak signal intensity, fluorescence interference, and inherent trade-offs between spectral resolution and the signal-to-noise ratio. Recent advances in silicon photonics present promising solutions by facilitating efficient light collection, enhancing optical fields via high-index-contrast waveguides, and allowing compact integration of photonic components. This work introduces a numerical analysis of an integrated digital Fourier transform spectrometer implemented on a silicon-nitride (SiN) platform, specifically designed for Raman spectroscopy. The proposed system employs a switch-based digital Fourier transform spectrometer architecture coupled with a single optical power meter for detection. Utilizing a regularized regression method, we successfully reconstructed Raman spectra in the 800 cm<sup>-1</sup> to 1800 cm<sup>-1</sup> range, covering spectra of both benign and malignant skin lesions. Our results demonstrate the capability of the proposed system to effectively differentiate various skin cancer types, highlighting its feasibility as a non-invasive diagnostic sensor.</p>","PeriodicalId":21698,"journal":{"name":"Sensors","volume":"25 12","pages":""},"PeriodicalIF":3.4000,"publicationDate":"2025-06-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Sensors","FirstCategoryId":"103","ListUrlMain":"https://doi.org/10.3390/s25123792","RegionNum":3,"RegionCategory":"综合性期刊","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Early detection and continuous monitoring of diseases are critical to improving patient outcomes, treatment adherence, and diagnostic accuracy. Traditional melanoma diagnosis relies primarily on visual assessment and biopsy, with reported accuracies ranging from 50% to 90% and significant inter-observer variability. Among emerging diagnostic technologies, Raman spectroscopy has demonstrated considerable promise for non-invasive disease detection, particularly in early-stage skin cancer identification. A portable, real-time Raman spectroscopy system could significantly enhance diagnostic precision, reduce biopsy reliance, and expedite diagnosis. However, miniaturization of Raman spectrometers for portable use faces significant challenges, including weak signal intensity, fluorescence interference, and inherent trade-offs between spectral resolution and the signal-to-noise ratio. Recent advances in silicon photonics present promising solutions by facilitating efficient light collection, enhancing optical fields via high-index-contrast waveguides, and allowing compact integration of photonic components. This work introduces a numerical analysis of an integrated digital Fourier transform spectrometer implemented on a silicon-nitride (SiN) platform, specifically designed for Raman spectroscopy. The proposed system employs a switch-based digital Fourier transform spectrometer architecture coupled with a single optical power meter for detection. Utilizing a regularized regression method, we successfully reconstructed Raman spectra in the 800 cm-1 to 1800 cm-1 range, covering spectra of both benign and malignant skin lesions. Our results demonstrate the capability of the proposed system to effectively differentiate various skin cancer types, highlighting its feasibility as a non-invasive diagnostic sensor.
期刊介绍:
Sensors (ISSN 1424-8220) provides an advanced forum for the science and technology of sensors and biosensors. It publishes reviews (including comprehensive reviews on the complete sensors products), regular research papers and short notes. Our aim is to encourage scientists to publish their experimental and theoretical results in as much detail as possible. There is no restriction on the length of the papers. The full experimental details must be provided so that the results can be reproduced.