A new indwelling urethral catheter (amSafeX) to verify the position of its balloon within the bladder during inflation

Anil Mandhani , Sunil Singh , Jakesh Reddy , Shrey Jain , Ramniwas Yadav
{"title":"A new indwelling urethral catheter (amSafeX) to verify the position of its balloon within the bladder during inflation","authors":"Anil Mandhani ,&nbsp;Sunil Singh ,&nbsp;Jakesh Reddy ,&nbsp;Shrey Jain ,&nbsp;Ramniwas Yadav","doi":"10.1016/j.urolvj.2025.100343","DOIUrl":null,"url":null,"abstract":"<div><h3>Introduction</h3><div>Inserting a Foley catheter for urethral catheterization can lead to numerous iatrogenic injuries in patients, as it is difficult to ensure that the balloon is in the bladder during inflation. This video demonstrates the safety and effectiveness of a new design of indwelling urethral catheter (amSafeX) that confirms the presence of the balloon in the bladder during inflation.</div></div><div><h3>Design, setting, and participants</h3><div>One hundred male patients who required a catheter for various reasons and 25 female postoperative patients were included in a prospective non-randomized interventional study. They were catheterized using the amSafeX catheter by a nurse or trainee doctor. The catheter features two draining eyes, with an additional eye proximal to the balloon and the usual distal eye blocked with an internal obturator attached to the string coming out of the drainage port. Standard instructions were given to follow the iSIP protocol of urethral catheterization. Data were collected and analyzed for the safety and efficacy of catheterization.</div></div><div><h3>Result</h3><div>From Jan 2022 to Oct 2022, none of the 125 patients had any adverse events during catheterization, and the obturator could be removed easily in all procedures. There were no incidents of peri‑catheter leakage or urethral injury recorded during catheterization. The median duration of catheterization was 5 (3–12) days.</div></div><div><h3>Conclusion</h3><div>The innovative design of amSafeX indwelling urethral catheter ensured that the bulb was always present in the bladder during inflation. This may eliminate the risk of urethral injury.</div></div>","PeriodicalId":92972,"journal":{"name":"Urology video journal","volume":"27 ","pages":"Article 100343"},"PeriodicalIF":0.0000,"publicationDate":"2025-05-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Urology video journal","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2590089725000192","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction

Inserting a Foley catheter for urethral catheterization can lead to numerous iatrogenic injuries in patients, as it is difficult to ensure that the balloon is in the bladder during inflation. This video demonstrates the safety and effectiveness of a new design of indwelling urethral catheter (amSafeX) that confirms the presence of the balloon in the bladder during inflation.

Design, setting, and participants

One hundred male patients who required a catheter for various reasons and 25 female postoperative patients were included in a prospective non-randomized interventional study. They were catheterized using the amSafeX catheter by a nurse or trainee doctor. The catheter features two draining eyes, with an additional eye proximal to the balloon and the usual distal eye blocked with an internal obturator attached to the string coming out of the drainage port. Standard instructions were given to follow the iSIP protocol of urethral catheterization. Data were collected and analyzed for the safety and efficacy of catheterization.

Result

From Jan 2022 to Oct 2022, none of the 125 patients had any adverse events during catheterization, and the obturator could be removed easily in all procedures. There were no incidents of peri‑catheter leakage or urethral injury recorded during catheterization. The median duration of catheterization was 5 (3–12) days.

Conclusion

The innovative design of amSafeX indwelling urethral catheter ensured that the bulb was always present in the bladder during inflation. This may eliminate the risk of urethral injury.
一种新的留置导尿管(amSafeX),用于在充气期间验证其球囊在膀胱内的位置
导尿时插入Foley导尿管会导致许多医源性损伤,因为在充气过程中很难确保气囊在膀胱内。本视频展示了一种新型留置导尿管(amSafeX)的安全性和有效性,该导尿管可在充气过程中确认膀胱内气囊的存在。设计、环境和参与者100名因各种原因需要导管的男性患者和25名女性术后患者被纳入一项前瞻性非随机介入研究。由护士或实习医生使用amSafeX导管进行导尿。导管有两只排液眼,另一只眼位于球囊近端,另一只眼位于通常的远端,另一只眼被内闭孔堵住,内闭孔连接到从排液口伸出的管子上。给出了遵循iSIP导尿方案的标准说明。收集数据并分析置管的安全性和有效性。结果从2022年1月至2022年10月,125例患者在置管过程中均无不良事件发生,所有手术均可轻松取出闭孔。在置管过程中没有发生导管周围渗漏或尿道损伤的记录。中位置管时间为5(3-12)天。结论amSafeX留置导尿管的创新设计保证了膀胱充气过程中球囊始终在膀胱内。这可以消除尿道损伤的风险。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Urology video journal
Urology video journal Nephrology, Urology
自引率
0.00%
发文量
0
审稿时长
20 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信