Intraocular lens position outcomes in modified Yamane's technique: The comparison of anterior vitrectomy versus pars plana vitrectomy.

IF 2.1 4区 医学 Q2 OPHTHALMOLOGY
Cemile Ucgul Atilgan, Kemal Tekin, Merve Temmuz Aydugan, Pinar Kosekahya, Ali Kosekahya, Mehmet Citirik
{"title":"Intraocular lens position outcomes in modified Yamane's technique: The comparison of anterior vitrectomy versus pars plana vitrectomy.","authors":"Cemile Ucgul Atilgan, Kemal Tekin, Merve Temmuz Aydugan, Pinar Kosekahya, Ali Kosekahya, Mehmet Citirik","doi":"10.4103/IJO.IJO_2927_24","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate the differences in intraocular lens (IOL) decentration, tilt, and lenticular astigmatism between Yamane's IOL fixations combined with pars plana vitrectomy (PPV) or anterior vitrectomy (AV), as well as compare those results with standard phacoemulsification surgery at the sixth month.</p><p><strong>Methods: </strong>This prospective longitudinal comparative study included 20 eyes treated with Yamane's IOL fixation combined with AV (AV group), 20 eyes treated with Yamane's IOL fixation combined with PPV (PPV group), and 20 eyes that underwent standard phacoemulsification with the implantation of a foldable IOL in the capsular bag as controls (Phaco group). IOL decentration, tilt, and lenticular astigmatism values were compared between the groups.</p><p><strong>Results: </strong>The horizontal tilt angle was statistically significantly lower in the Phaco group compared to the PPV and AV groups, while no significant differences existed between the PPV and AV groups. The mean values of horizontal decentration, vertical decentration, and vertical tilt 6 months postoperatively showed no statistically significant differences between the three groups (P > 0.05 for all), while all parameters were lower in the Phaco group. Moreover, no statistically significant differences existed in accordance with the mean lenticular astigmatism 6 months postoperatively between the three groups (P = 0.969).</p><p><strong>Conclusion: </strong>AV or PPV combined with Yamane's technique exhibited similar IOL decentration, tilt, and lenticular astigmatism at 6 months.</p>","PeriodicalId":13329,"journal":{"name":"Indian Journal of Ophthalmology","volume":" ","pages":""},"PeriodicalIF":2.1000,"publicationDate":"2025-04-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Indian Journal of Ophthalmology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.4103/IJO.IJO_2927_24","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To evaluate the differences in intraocular lens (IOL) decentration, tilt, and lenticular astigmatism between Yamane's IOL fixations combined with pars plana vitrectomy (PPV) or anterior vitrectomy (AV), as well as compare those results with standard phacoemulsification surgery at the sixth month.

Methods: This prospective longitudinal comparative study included 20 eyes treated with Yamane's IOL fixation combined with AV (AV group), 20 eyes treated with Yamane's IOL fixation combined with PPV (PPV group), and 20 eyes that underwent standard phacoemulsification with the implantation of a foldable IOL in the capsular bag as controls (Phaco group). IOL decentration, tilt, and lenticular astigmatism values were compared between the groups.

Results: The horizontal tilt angle was statistically significantly lower in the Phaco group compared to the PPV and AV groups, while no significant differences existed between the PPV and AV groups. The mean values of horizontal decentration, vertical decentration, and vertical tilt 6 months postoperatively showed no statistically significant differences between the three groups (P > 0.05 for all), while all parameters were lower in the Phaco group. Moreover, no statistically significant differences existed in accordance with the mean lenticular astigmatism 6 months postoperatively between the three groups (P = 0.969).

Conclusion: AV or PPV combined with Yamane's technique exhibited similar IOL decentration, tilt, and lenticular astigmatism at 6 months.

改良Yamane技术对人工晶状体位置的影响:玻璃体前体切除术与玻璃体平面部切除术的比较。
目的:评价Yamane人工晶状体植入术联合玻璃体前部切除术(AV)或玻璃体前部切除术(PPV)在人工晶状体(IOL)脱位、倾斜和晶状体散光方面的差异,并与标准超声乳化手术在6个月时的结果进行比较。方法:采用Yamane’s IOL联合AV固定20眼(AV组),Yamane’s IOL联合PPV固定20眼(PPV组),以及采用标准超声乳化术并在囊袋内植入可折叠IOL作为对照(Phaco组)。比较两组人工晶状体的离体、倾斜和晶状体散光值。结果:Phaco组水平倾斜角较PPV、AV组明显降低,PPV、AV组间差异无统计学意义。术后6个月三组间水平偏移、垂直偏移、垂直倾斜的平均值差异无统计学意义(P < 0.05),而Phaco组各参数均较低。三组患者术后6个月平均晶状体散光比较,差异均无统计学意义(P = 0.969)。结论:AV或PPV联合Yamane技术在6个月时表现出相似的人工晶状体脱位、倾斜和晶状体散光。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
3.80
自引率
19.40%
发文量
1963
审稿时长
38 weeks
期刊介绍: Indian Journal of Ophthalmology covers clinical, experimental, basic science research and translational research studies related to medical, ethical and social issues in field of ophthalmology and vision science. Articles with clinical interest and implications will be given preference.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信