Arman Tsaturyan, Eugenio Ventimiglia, Arkadya Musayelyan, Hayk Grigoryan, Marat Harutyunyan, Gagik Amirjanyan, Armen Muradyan, Marine Khaskhazyan, Angelis Peteinaris, Vasileios Tatanis, Evangelos Liatsikos, Panagiotis Kallidonis, Francesco Esperto, Patrick Juliebø-Jones, Lazaros Tzelves, Ali Talyshinskii, Bhaskar Somani, Amelia Pietropaolo
{"title":"Relocation of big stone fragments with direct-in scope suction.","authors":"Arman Tsaturyan, Eugenio Ventimiglia, Arkadya Musayelyan, Hayk Grigoryan, Marat Harutyunyan, Gagik Amirjanyan, Armen Muradyan, Marine Khaskhazyan, Angelis Peteinaris, Vasileios Tatanis, Evangelos Liatsikos, Panagiotis Kallidonis, Francesco Esperto, Patrick Juliebø-Jones, Lazaros Tzelves, Ali Talyshinskii, Bhaskar Somani, Amelia Pietropaolo","doi":"10.1007/s00345-025-05594-5","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To investigate the effectiveness of DISS feature of novel 7.5Fr and 9.2Fr single-use flexible digital ureteroscopes to relocate and evacuate stone fragments (2-5 mm in diameter) without any accessory instruments.</p><p><strong>Methods: </strong>An ex-vivo experimental study on porcine kidney and ureter was performed. Natural calcium oxalate dihydrate stone fragments sized 2-5 mm placed in the upper, middle and lower calyces were used. For each stone in each location 5 attempts were performed. The attempt was defined as successful if stone evacuation was reported while withdrawing the scope through the 12/14Fr UAS. The time collapsing the collecting system was also reported.</p><p><strong>Results: </strong>The time needed to collapse the porcine pelvi-calyceal system (PCS) was 4-5 s for 9.2Fr and 5-6 s for 7.5Fr scope. Evacuation of 2 mm stone fragments occurred in all trials both with 9.2Fr and 7.5Fr scopes. In case of 3 mm stone, evacuation of stone fragments was observed in 3 out of 5 and 1 out of 5 attempts in upper calyx, 5 out of 5 and 3 out of 5 in the middle calyx and 2 out of 5 and 0 out 5 in lower calyx using 7.5Fr and 9.2Fr scope, respectively.</p><p><strong>Conclusion: </strong>The DISS feature of the novel 7.5Fr and 9.2Fr single-use digital flexible ureteroscope can be potentially used not only to aspirate dust but also to relocate and evacuate larger stone fragments up to 4 mm in diameter using only suction. The speed of collapse of the PCS seems to be one of the main predictors of success.</p>","PeriodicalId":23954,"journal":{"name":"World Journal of Urology","volume":"43 1","pages":"210"},"PeriodicalIF":2.8000,"publicationDate":"2025-04-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"World Journal of Urology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00345-025-05594-5","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"UROLOGY & NEPHROLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To investigate the effectiveness of DISS feature of novel 7.5Fr and 9.2Fr single-use flexible digital ureteroscopes to relocate and evacuate stone fragments (2-5 mm in diameter) without any accessory instruments.

Methods: An ex-vivo experimental study on porcine kidney and ureter was performed. Natural calcium oxalate dihydrate stone fragments sized 2-5 mm placed in the upper, middle and lower calyces were used. For each stone in each location 5 attempts were performed. The attempt was defined as successful if stone evacuation was reported while withdrawing the scope through the 12/14Fr UAS. The time collapsing the collecting system was also reported.

Results: The time needed to collapse the porcine pelvi-calyceal system (PCS) was 4-5 s for 9.2Fr and 5-6 s for 7.5Fr scope. Evacuation of 2 mm stone fragments occurred in all trials both with 9.2Fr and 7.5Fr scopes. In case of 3 mm stone, evacuation of stone fragments was observed in 3 out of 5 and 1 out of 5 attempts in upper calyx, 5 out of 5 and 3 out of 5 in the middle calyx and 2 out of 5 and 0 out 5 in lower calyx using 7.5Fr and 9.2Fr scope, respectively.

Conclusion: The DISS feature of the novel 7.5Fr and 9.2Fr single-use digital flexible ureteroscope can be potentially used not only to aspirate dust but also to relocate and evacuate larger stone fragments up to 4 mm in diameter using only suction. The speed of collapse of the PCS seems to be one of the main predictors of success.

直入式吸力大石片搬迁。
目的:探讨新型7.5Fr和9.2Fr一次性柔性输尿管镜的DISS特征在不使用任何辅助器械的情况下对直径2 ~ 5mm的结石碎片进行定位和排出的效果。方法:对猪肾脏和输尿管进行离体实验研究。采用大小为2-5毫米的天然草酸钙二水合物石片,放置于上、中、下萼。对于每个位置的每块石头,进行了5次尝试。如果在通过12/14Fr UAS取出瞄准镜时报告了石头撤离,则该尝试被定义为成功。还报道了收集系统崩溃的时间。结果:猪盆腔-盏系统(PCS)在9.2Fr时塌陷时间为4 ~ 5 s,在7.5Fr时塌陷时间为5 ~ 6 s。在9.2Fr和7.5Fr范围内的所有试验中,都发生了2mm结石碎片的排出。在3毫米结石的情况下,在7.5Fr和9.2Fr的范围内,在上部花萼的5次尝试中有3次和5次尝试中有1次,在中部花萼的5次尝试中有5次和5次尝试中有3次和5次尝试中有3次,在下部花萼的5次尝试中有2次和5次尝试中有0次。结论:新型7.5Fr和9.2Fr一次性数字输尿管镜的DISS功能不仅可以用于吸尘,还可以用于仅吸力即可定位和排出直径达4mm的较大结石碎片。个人电脑崩溃的速度似乎是成功的主要预测因素之一。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
World Journal of Urology
World Journal of Urology 医学-泌尿学与肾脏学
CiteScore
6.80
自引率
8.80%
发文量
317
审稿时长
4-8 weeks
期刊介绍: The WORLD JOURNAL OF UROLOGY conveys regularly the essential results of urological research and their practical and clinical relevance to a broad audience of urologists in research and clinical practice. In order to guarantee a balanced program, articles are published to reflect the developments in all fields of urology on an internationally advanced level. Each issue treats a main topic in review articles of invited international experts. Free papers are unrelated articles to the main topic.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信