{"title":"Removal of a 'cold-welded' femoral head lag screw in a nail combination.","authors":"Ryan J Campbell, Michael Symes, Brahman Sivakumar, Zac Dragan, Stephen Ruff, Andrew Ellis","doi":"10.1136/bcr-2024-264090","DOIUrl":null,"url":null,"abstract":"<p><p>We present a case of a femoral head lag screw 'cold welded' to an intramedullary nail (IMN) in a female in her 20s during exchange femoral nailing of a subtrochanteric femoral osteotomy non-union. We subsequently developed a reverse spiral-fluted bolt extraction socket, designed to engage the outer wall of a bolt or screw. The lag screw was removed from the Smith and Nephew Meta-Tan IMN, 1 week later, and exchange nailing was successfully completed. This case report describes a technically challenging situation of a cold-welded femoral head lag screw during a complex revision. This report introduces a novel removal device and technique for such cases.</p>","PeriodicalId":9080,"journal":{"name":"BMJ Case Reports","volume":"18 3","pages":""},"PeriodicalIF":0.6000,"publicationDate":"2025-03-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11937885/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"BMJ Case Reports","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1136/bcr-2024-264090","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
引用次数: 0
Abstract
We present a case of a femoral head lag screw 'cold welded' to an intramedullary nail (IMN) in a female in her 20s during exchange femoral nailing of a subtrochanteric femoral osteotomy non-union. We subsequently developed a reverse spiral-fluted bolt extraction socket, designed to engage the outer wall of a bolt or screw. The lag screw was removed from the Smith and Nephew Meta-Tan IMN, 1 week later, and exchange nailing was successfully completed. This case report describes a technically challenging situation of a cold-welded femoral head lag screw during a complex revision. This report introduces a novel removal device and technique for such cases.
期刊介绍:
BMJ Case Reports is an important educational resource offering a high volume of cases in all disciplines so that healthcare professionals, researchers and others can easily find clinically important information on common and rare conditions. All articles are peer reviewed and copy edited before publication. BMJ Case Reports is not an edition or supplement of the BMJ.