{"title":"Phosphorous determination in nuclear reactor materials: dysprosium titanate, titanium dioxide and uranium oxide","authors":"Poonam Verma, U. K. Thakur, S. Jeyakumar","doi":"10.1007/s10967-024-09916-6","DOIUrl":null,"url":null,"abstract":"<div><p>A reliable analytical methodology is developed to determine phosphorus as phosphate in nuclear matrices viz uranium oxide, TiO<sub>2</sub> and dysprosium titanate by spectrophotometric molybdenum blue method. Refractory matrices (TiO<sub>2</sub> and dysprosium titanate) are dissolved employing microwave technique. Calibration is linear in the concentration range from 0.1 to 1.0 ppm of phosphorous with r<sup>2</sup> better than 0.9989. LOD obtained is 0.03 ppm. Method and instrumental RSD is 1 and 0.3%, respectively at 0.33 ppm level. Recovery of P at 0.33 ppm level is better than 95%. The developed method is validated by comparing results obtained by ion chromatography.</p></div>","PeriodicalId":661,"journal":{"name":"Journal of Radioanalytical and Nuclear Chemistry","volume":"334 3","pages":"2281 - 2289"},"PeriodicalIF":1.5000,"publicationDate":"2024-12-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://link.springer.com/content/pdf/10.1007/s10967-024-09916-6.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Radioanalytical and Nuclear Chemistry","FirstCategoryId":"92","ListUrlMain":"https://link.springer.com/article/10.1007/s10967-024-09916-6","RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0
Abstract
A reliable analytical methodology is developed to determine phosphorus as phosphate in nuclear matrices viz uranium oxide, TiO2 and dysprosium titanate by spectrophotometric molybdenum blue method. Refractory matrices (TiO2 and dysprosium titanate) are dissolved employing microwave technique. Calibration is linear in the concentration range from 0.1 to 1.0 ppm of phosphorous with r2 better than 0.9989. LOD obtained is 0.03 ppm. Method and instrumental RSD is 1 and 0.3%, respectively at 0.33 ppm level. Recovery of P at 0.33 ppm level is better than 95%. The developed method is validated by comparing results obtained by ion chromatography.
期刊介绍:
An international periodical publishing original papers, letters, review papers and short communications on nuclear chemistry. The subjects covered include: Nuclear chemistry, Radiochemistry, Radiation chemistry, Radiobiological chemistry, Environmental radiochemistry, Production and control of radioisotopes and labelled compounds, Nuclear power plant chemistry, Nuclear fuel chemistry, Radioanalytical chemistry, Radiation detection and measurement, Nuclear instrumentation and automation, etc.