Standardization of gamma-ray spectrometry using the NaI (TI) scintillation detector

IF 1.5 3区 化学 Q3 CHEMISTRY, ANALYTICAL
Nagraj Channappa, B. R. Kerur
{"title":"Standardization of gamma-ray spectrometry using the NaI (TI) scintillation detector","authors":"Nagraj Channappa,&nbsp;B. R. Kerur","doi":"10.1007/s10967-024-09648-7","DOIUrl":null,"url":null,"abstract":"<div><p>The NaI (Tl) scintillation detector is versatile and widely used in the field of radiation detection and measurement studies. In the present paper, a 4 × 4 NaI (Tl) scintillation detector’s efficiency and resolution are based on parameters viz., calibration, and geometries studied. The standard radioactive sources used for energy calibration studies found resolutions of 8.1%, 6.0%, 5.5%, and 4.1% for gamma-ray energies of 660.37 keV, 1175 keV, 1333.99 keV, and 2502.77 keV, respectively. The NaI (Tl) detector shows an efficiency of 3.51%, 2.09%, 0.67%, and 0.38%, respectively, for the above energies, which is in linearity with detector parameters.</p></div>","PeriodicalId":661,"journal":{"name":"Journal of Radioanalytical and Nuclear Chemistry","volume":"334 3","pages":"2171 - 2176"},"PeriodicalIF":1.5000,"publicationDate":"2025-01-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Radioanalytical and Nuclear Chemistry","FirstCategoryId":"92","ListUrlMain":"https://link.springer.com/article/10.1007/s10967-024-09648-7","RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

The NaI (Tl) scintillation detector is versatile and widely used in the field of radiation detection and measurement studies. In the present paper, a 4 × 4 NaI (Tl) scintillation detector’s efficiency and resolution are based on parameters viz., calibration, and geometries studied. The standard radioactive sources used for energy calibration studies found resolutions of 8.1%, 6.0%, 5.5%, and 4.1% for gamma-ray energies of 660.37 keV, 1175 keV, 1333.99 keV, and 2502.77 keV, respectively. The NaI (Tl) detector shows an efficiency of 3.51%, 2.09%, 0.67%, and 0.38%, respectively, for the above energies, which is in linearity with detector parameters.

Abstract Image

使用NaI (TI)闪烁探测器的伽玛射线光谱标准化
NaI (Tl)闪烁探测器用途广泛,广泛应用于辐射探测和测量研究领域。本文对4 × 4 NaI (Tl)闪烁探测器的效率和分辨率进行了基于参数(即校准和几何形状)的研究。用于能量校准研究的标准放射源对γ射线能量分别为660.37 keV、1175 keV、1333.99 keV和2502.77 keV的分辨率分别为8.1%、6.0%、5.5%和4.1%。NaI (Tl)探测器对上述能量的效率分别为3.51%、2.09%、0.67%和0.38%,且与探测器参数呈线性关系。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
2.80
自引率
18.80%
发文量
504
审稿时长
2.2 months
期刊介绍: An international periodical publishing original papers, letters, review papers and short communications on nuclear chemistry. The subjects covered include: Nuclear chemistry, Radiochemistry, Radiation chemistry, Radiobiological chemistry, Environmental radiochemistry, Production and control of radioisotopes and labelled compounds, Nuclear power plant chemistry, Nuclear fuel chemistry, Radioanalytical chemistry, Radiation detection and measurement, Nuclear instrumentation and automation, etc.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信