A method for adjusting the effective decay constant of a radon exhalation simulation device

IF 1.5 3区 化学 Q3 CHEMISTRY, ANALYTICAL
Zhipeng Liu, Tao Hu, Zhongkai Fan, Huiying Li, Jiale Sun, Xinyue Yang, Jia Liu, Haibo Yi, Jiulin Wu, Hongzhi Yuan, Yanliang Tan
{"title":"A method for adjusting the effective decay constant of a radon exhalation simulation device","authors":"Zhipeng Liu,&nbsp;Tao Hu,&nbsp;Zhongkai Fan,&nbsp;Huiying Li,&nbsp;Jiale Sun,&nbsp;Xinyue Yang,&nbsp;Jia Liu,&nbsp;Haibo Yi,&nbsp;Jiulin Wu,&nbsp;Hongzhi Yuan,&nbsp;Yanliang Tan","doi":"10.1007/s10967-024-09963-z","DOIUrl":null,"url":null,"abstract":"<div><p>In this paper, a method and its device were designed to quickly adjust the effective decay constant <i>λ</i><sub>EFF</sub> of a radon exhalation simulation device. The device achieves the purpose of adjusting<i> λ</i><sub>EFF</sub> by actively adjusting the leakage rate of the device. The <i>λ</i><sub>EFF</sub> of the initial radon exhalation simulation device was measured firstly. then five different sets of <i>λ</i><sub>EFF</sub> adjustment experiments were set. The error between the actual value of <i>λ</i><sub>EFF</sub> and the target value of<i> λ</i><sub>EFF</sub> calculated from the five experiments was within 2 standard deviations. This shows that the method of adjusting <i>λ</i><sub><i>E</i>FF</sub> of the device is correct.</p></div>","PeriodicalId":661,"journal":{"name":"Journal of Radioanalytical and Nuclear Chemistry","volume":"334 3","pages":"2013 - 2021"},"PeriodicalIF":1.5000,"publicationDate":"2025-01-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Radioanalytical and Nuclear Chemistry","FirstCategoryId":"92","ListUrlMain":"https://link.springer.com/article/10.1007/s10967-024-09963-z","RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

In this paper, a method and its device were designed to quickly adjust the effective decay constant λEFF of a radon exhalation simulation device. The device achieves the purpose of adjusting λEFF by actively adjusting the leakage rate of the device. The λEFF of the initial radon exhalation simulation device was measured firstly. then five different sets of λEFF adjustment experiments were set. The error between the actual value of λEFF and the target value of λEFF calculated from the five experiments was within 2 standard deviations. This shows that the method of adjusting λEFF of the device is correct.

求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
2.80
自引率
18.80%
发文量
504
审稿时长
2.2 months
期刊介绍: An international periodical publishing original papers, letters, review papers and short communications on nuclear chemistry. The subjects covered include: Nuclear chemistry, Radiochemistry, Radiation chemistry, Radiobiological chemistry, Environmental radiochemistry, Production and control of radioisotopes and labelled compounds, Nuclear power plant chemistry, Nuclear fuel chemistry, Radioanalytical chemistry, Radiation detection and measurement, Nuclear instrumentation and automation, etc.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信