A comparative study of long-term measurements of natural gamma absorbed dose rate in outdoor air by TLD and GM detectors

IF 1.5 3区 化学 Q3 CHEMISTRY, ANALYTICAL
Pratip Mitra, S. K. Sahu, A. Vinod Kumar
{"title":"A comparative study of long-term measurements of natural gamma absorbed dose rate in outdoor air by TLD and GM detectors","authors":"Pratip Mitra,&nbsp;S. K. Sahu,&nbsp;A. Vinod Kumar","doi":"10.1007/s10967-024-09946-0","DOIUrl":null,"url":null,"abstract":"<div><p>This paper investigates and compares two widely employed techniques for measuring natural gamma absorbed dose rate in outdoor air: the thermoluminescent dosimeter (TLD) and the Geiger-Mueller (GM) detector-based environmental radiation monitor (ERM). Over two decades (2003–2023), measurements were conducted at eighteen investigation sites having a wide variation of local dose rate values. The TLDs accumulated quarterly doses, while the ERMs recorded hourly dose rates. The comparison of mean dose rates obtained by the two methods agreed within ± 30% for all sites. A strong positive correlation was obtained between the two methods.</p></div>","PeriodicalId":661,"journal":{"name":"Journal of Radioanalytical and Nuclear Chemistry","volume":"334 3","pages":"2391 - 2396"},"PeriodicalIF":1.5000,"publicationDate":"2025-01-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://link.springer.com/content/pdf/10.1007/s10967-024-09946-0.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Radioanalytical and Nuclear Chemistry","FirstCategoryId":"92","ListUrlMain":"https://link.springer.com/article/10.1007/s10967-024-09946-0","RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

This paper investigates and compares two widely employed techniques for measuring natural gamma absorbed dose rate in outdoor air: the thermoluminescent dosimeter (TLD) and the Geiger-Mueller (GM) detector-based environmental radiation monitor (ERM). Over two decades (2003–2023), measurements were conducted at eighteen investigation sites having a wide variation of local dose rate values. The TLDs accumulated quarterly doses, while the ERMs recorded hourly dose rates. The comparison of mean dose rates obtained by the two methods agreed within ± 30% for all sites. A strong positive correlation was obtained between the two methods.

TLD和GM探测器长期测量室外空气中自然伽马吸收剂量率的比较研究
本文研究并比较了两种广泛使用的测量室外空气中自然伽马吸收剂量率的技术:热释光剂量计(TLD)和基于盖格-穆勒(GM)探测器的环境辐射监测仪(ERM)。在二十年(2003-2023年)期间,在当地剂量率值变化很大的18个调查点进行了测量。顶级区域按季度累积剂量,而辐射管理单位则按小时记录剂量率。两种方法得到的平均剂量率比较在±30%范围内一致。两种方法之间有很强的正相关。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
2.80
自引率
18.80%
发文量
504
审稿时长
2.2 months
期刊介绍: An international periodical publishing original papers, letters, review papers and short communications on nuclear chemistry. The subjects covered include: Nuclear chemistry, Radiochemistry, Radiation chemistry, Radiobiological chemistry, Environmental radiochemistry, Production and control of radioisotopes and labelled compounds, Nuclear power plant chemistry, Nuclear fuel chemistry, Radioanalytical chemistry, Radiation detection and measurement, Nuclear instrumentation and automation, etc.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信