{"title":"Differences Between the Unipolar Versus Bipolar Potential-Based Activation Maps of Ventricular Premature Contractions Arising From Ventricular Outflow Tracts.","authors":"Yoshimori J An, Masafumi Sugawara, Jakub Sroubek, Katsuhide Hayashi, John O Lopez, Justin Lee, Shady Nakhla, Pasquale Santangeli, Oussama M Wazni, Koji Higuchi","doi":"10.1111/jce.16647","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The use of an automated annotation algorithm based on the maximal negative derivative of the unipolar potential (-dV/dTmax) for local activation timing in the ablation of outflow tract (OT) ventricular premature contractions (VPCs) remains controversial.</p><p><strong>Objective: </strong>To investigate the spatial differences in the earliest activation sites (EASs) of OT-VPCs identified by an automated annotation based on unipolar -dV/dTmax versus manual annotation using local bipolar potentials.</p><p><strong>Methods: </strong>Seventy-nine patients with frequent OT-VPCs who underwent successful ablation were included. VPCs originated from the right ventricular OT (RVOT) free wall (n = 10), RVOT septum (n = 25), aortomitral continuity (AMC) (n = 19), and aortic sinus cusps (ASCs) (n = 25). The spatial distance between EASs identified by the two annotation methods was analyzed.</p><p><strong>Results: </strong>The spatial distance between EASs was significantly larger in ASC-origin VPCs compared to non-ASC-origin VPCs (median: 11.9 mm [IQR: 7.9-14.9] vs. 1.2 mm [IQR: 0.0-3.3], p < 0.001). Among non-ASC-origin VPCs, the spatial difference was smallest in VPCs from the RVOT free wall (median: 0 mm) and larger in those from the RVOT septum (median: 1.6 mm) and AMC (median: 2.2 mm).</p><p><strong>Conclusion: </strong>The spatial discordance of EAS between unipolar and bipolar mapping varies by the VPC origin site. The discrepancy is particularly pronounced in ASC-origin VPCs, emphasizing the need for careful interpretation of automated annotation algorithms to ensure accurate localization and effective ablation.</p>","PeriodicalId":15178,"journal":{"name":"Journal of Cardiovascular Electrophysiology","volume":" ","pages":""},"PeriodicalIF":2.3000,"publicationDate":"2025-03-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Cardiovascular Electrophysiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/jce.16647","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0
Abstract
Background: The use of an automated annotation algorithm based on the maximal negative derivative of the unipolar potential (-dV/dTmax) for local activation timing in the ablation of outflow tract (OT) ventricular premature contractions (VPCs) remains controversial.
Objective: To investigate the spatial differences in the earliest activation sites (EASs) of OT-VPCs identified by an automated annotation based on unipolar -dV/dTmax versus manual annotation using local bipolar potentials.
Methods: Seventy-nine patients with frequent OT-VPCs who underwent successful ablation were included. VPCs originated from the right ventricular OT (RVOT) free wall (n = 10), RVOT septum (n = 25), aortomitral continuity (AMC) (n = 19), and aortic sinus cusps (ASCs) (n = 25). The spatial distance between EASs identified by the two annotation methods was analyzed.
Results: The spatial distance between EASs was significantly larger in ASC-origin VPCs compared to non-ASC-origin VPCs (median: 11.9 mm [IQR: 7.9-14.9] vs. 1.2 mm [IQR: 0.0-3.3], p < 0.001). Among non-ASC-origin VPCs, the spatial difference was smallest in VPCs from the RVOT free wall (median: 0 mm) and larger in those from the RVOT septum (median: 1.6 mm) and AMC (median: 2.2 mm).
Conclusion: The spatial discordance of EAS between unipolar and bipolar mapping varies by the VPC origin site. The discrepancy is particularly pronounced in ASC-origin VPCs, emphasizing the need for careful interpretation of automated annotation algorithms to ensure accurate localization and effective ablation.
期刊介绍:
Journal of Cardiovascular Electrophysiology (JCE) keeps its readership well informed of the latest developments in the study and management of arrhythmic disorders. Edited by Bradley P. Knight, M.D., and a distinguished international editorial board, JCE is the leading journal devoted to the study of the electrophysiology of the heart.