Impact of Vitamin E-Coated Membrane Hemodiafilter on Serum Albumin Redox State in the Acute Kidney Injury Pig Hemodialysis Model.

IF 2.2 3区 医学 Q3 ENGINEERING, BIOMEDICAL
Shouichi Fujimoto, Masahide Koremoto, Shushi Yamamoto, Hiroshi Umeno, Yusuke Sano, Toshihiro Tsuruda
{"title":"Impact of Vitamin E-Coated Membrane Hemodiafilter on Serum Albumin Redox State in the Acute Kidney Injury Pig Hemodialysis Model.","authors":"Shouichi Fujimoto, Masahide Koremoto, Shushi Yamamoto, Hiroshi Umeno, Yusuke Sano, Toshihiro Tsuruda","doi":"10.1111/aor.14982","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Several studies have evaluated the biocompatibility of dialysis membranes. The use of vitamin E-coated membranes has been reported multilaterally in in vitro and clinical studies. Nevertheless, the effect of vitamin E-coated membranes on the redox state of serum albumin, which forms the largest fraction of reactive sulfhydryl groups, has not been reported.</p><p><strong>Methods: </strong>Hemodiafiltration (HDF) with and without a vitamin E-coated hemodiafilter (V-RA<sup>TM</sup> group and ABH<sup>TM</sup> groups, respectively) was performed in an acute kidney injury pig model to determine whether changes in the serum albumin, the oxidized albumin (OxiALB), and the reduced albumin (RedALB) levels differ between the two groups.</p><p><strong>Results: </strong>Analyses were conducted 22-24 times in the V-RA<sup>TM</sup> group and 16-18 times in the ABH<sup>TM</sup> group, excluding missing data. The serum albumin levels decreased in both groups after nephrectomy; however, the decrease observed in the V-RA<sup>TM</sup> group was significantly lesser than that in the ABH<sup>TM</sup> group. RedALB levels were significantly higher in the V-RA<sup>TM</sup> group; in contrast, OxiALB levels did not differ between the two groups. A significant positive correlation was observed between the serum albumin and RedALB levels.</p><p><strong>Conclusions: </strong>The present study demonstrated that HDF performed using a vitamin E-coated hemodiafilter effectively minimized the reduction in serum albumin and RedALB levels compared to the vitamin E-non-coated hemodiafilter in an acute kidney injury pig model.</p>","PeriodicalId":8450,"journal":{"name":"Artificial organs","volume":" ","pages":""},"PeriodicalIF":2.2000,"publicationDate":"2025-03-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Artificial organs","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1111/aor.14982","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Several studies have evaluated the biocompatibility of dialysis membranes. The use of vitamin E-coated membranes has been reported multilaterally in in vitro and clinical studies. Nevertheless, the effect of vitamin E-coated membranes on the redox state of serum albumin, which forms the largest fraction of reactive sulfhydryl groups, has not been reported.

Methods: Hemodiafiltration (HDF) with and without a vitamin E-coated hemodiafilter (V-RATM group and ABHTM groups, respectively) was performed in an acute kidney injury pig model to determine whether changes in the serum albumin, the oxidized albumin (OxiALB), and the reduced albumin (RedALB) levels differ between the two groups.

Results: Analyses were conducted 22-24 times in the V-RATM group and 16-18 times in the ABHTM group, excluding missing data. The serum albumin levels decreased in both groups after nephrectomy; however, the decrease observed in the V-RATM group was significantly lesser than that in the ABHTM group. RedALB levels were significantly higher in the V-RATM group; in contrast, OxiALB levels did not differ between the two groups. A significant positive correlation was observed between the serum albumin and RedALB levels.

Conclusions: The present study demonstrated that HDF performed using a vitamin E-coated hemodiafilter effectively minimized the reduction in serum albumin and RedALB levels compared to the vitamin E-non-coated hemodiafilter in an acute kidney injury pig model.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Artificial organs
Artificial organs 工程技术-工程:生物医学
CiteScore
4.30
自引率
12.50%
发文量
303
审稿时长
4-8 weeks
期刊介绍: Artificial Organs is the official peer reviewed journal of The International Federation for Artificial Organs (Members of the Federation are: The American Society for Artificial Internal Organs, The European Society for Artificial Organs, and The Japanese Society for Artificial Organs), The International Faculty for Artificial Organs, the International Society for Rotary Blood Pumps, The International Society for Pediatric Mechanical Cardiopulmonary Support, and the Vienna International Workshop on Functional Electrical Stimulation. Artificial Organs publishes original research articles dealing with developments in artificial organs applications and treatment modalities and their clinical applications worldwide. Membership in the Societies listed above is not a prerequisite for publication. Articles are published without charge to the author except for color figures and excess page charges as noted.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信