The I-PREDICT 50th Percentile Male Finite Element Model: Development and Validation of the Torso.

IF 3 2区 医学 Q3 ENGINEERING, BIOMEDICAL
Zachary S Hostetler, Drew DiSerafino, Alex Kalmar-Gonzalo, Derek Jones, Lance Frazer, Dan Nicolella, Matthew Davis
{"title":"The I-PREDICT 50th Percentile Male Finite Element Model: Development and Validation of the Torso.","authors":"Zachary S Hostetler, Drew DiSerafino, Alex Kalmar-Gonzalo, Derek Jones, Lance Frazer, Dan Nicolella, Matthew Davis","doi":"10.1007/s10439-025-03704-3","DOIUrl":null,"url":null,"abstract":"<p><p>Behind Armor Blunt Trauma (BABT) is a phenomenon that occurs when energy is transferred from Personal Protective Equipment (PPE) to the human body and can range from minor to fatal injuries. The current standard to evaluate PPE uses Roma Plastilina No. 1 clay and has a poor correlation to human injuries. To provide a more suitable human surrogate for evaluating risk of injury and functional incapacitation due to BABT, the Incapacitation Prediction for Readiness in Expeditionary Domains: an Integrated Computational Tool (I-PREDICT) has developed a 50th percentile male human body model (HBM) to better understand injury mechanisms in the BABT environment. The model was developed using a hierarchical validation approach including component, regional, and whole torso level tests. Material properties were sourced from literature and I-PREDICT experimental test data, and the model was simulated in 25 different validation cases ranging from component level quasi-static tests to high-rate BABT impacts. The model was stable in all 25 simulations. CORrelation and Analysis (CORA) and BioRank were used to objectively quantify the model response. The average CORA and BioRank across all validation cases were 0.78 ± 0.18 and 0.68 ± 0.27, respectively, indicating 'good' agreement by CORA standards and 'excellent' by BioRank standards. When compared to high-rate BABT experimental impacts on post-mortem human subjects, the I-PREDICT HBM accurately predicted rib fracture probability. The ultimate goal of the I-PREDICT model is to predict injury and functional incapacitation for various in theater military applications. This study highlights the development and validation of the I-PREDICT torso and highlights initial BABT use cases.</p>","PeriodicalId":7986,"journal":{"name":"Annals of Biomedical Engineering","volume":" ","pages":""},"PeriodicalIF":3.0000,"publicationDate":"2025-03-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annals of Biomedical Engineering","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1007/s10439-025-03704-3","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Behind Armor Blunt Trauma (BABT) is a phenomenon that occurs when energy is transferred from Personal Protective Equipment (PPE) to the human body and can range from minor to fatal injuries. The current standard to evaluate PPE uses Roma Plastilina No. 1 clay and has a poor correlation to human injuries. To provide a more suitable human surrogate for evaluating risk of injury and functional incapacitation due to BABT, the Incapacitation Prediction for Readiness in Expeditionary Domains: an Integrated Computational Tool (I-PREDICT) has developed a 50th percentile male human body model (HBM) to better understand injury mechanisms in the BABT environment. The model was developed using a hierarchical validation approach including component, regional, and whole torso level tests. Material properties were sourced from literature and I-PREDICT experimental test data, and the model was simulated in 25 different validation cases ranging from component level quasi-static tests to high-rate BABT impacts. The model was stable in all 25 simulations. CORrelation and Analysis (CORA) and BioRank were used to objectively quantify the model response. The average CORA and BioRank across all validation cases were 0.78 ± 0.18 and 0.68 ± 0.27, respectively, indicating 'good' agreement by CORA standards and 'excellent' by BioRank standards. When compared to high-rate BABT experimental impacts on post-mortem human subjects, the I-PREDICT HBM accurately predicted rib fracture probability. The ultimate goal of the I-PREDICT model is to predict injury and functional incapacitation for various in theater military applications. This study highlights the development and validation of the I-PREDICT torso and highlights initial BABT use cases.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Annals of Biomedical Engineering
Annals of Biomedical Engineering 工程技术-工程:生物医学
CiteScore
7.50
自引率
15.80%
发文量
212
审稿时长
3 months
期刊介绍: Annals of Biomedical Engineering is an official journal of the Biomedical Engineering Society, publishing original articles in the major fields of bioengineering and biomedical engineering. The Annals is an interdisciplinary and international journal with the aim to highlight integrated approaches to the solutions of biological and biomedical problems.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信