Rapid detection of dynamic electrochemical impedance spectroscopy of batteries based on sampling function excitation

IF 8.1 2区 工程技术 Q1 CHEMISTRY, PHYSICAL
Yanlin Xiao , Lijun Yang , Xu Wu , Xiyang Zhong , Ping Wang , Yupeng Liu , Siquan Li , Wei Qin , Sidun Fang
{"title":"Rapid detection of dynamic electrochemical impedance spectroscopy of batteries based on sampling function excitation","authors":"Yanlin Xiao ,&nbsp;Lijun Yang ,&nbsp;Xu Wu ,&nbsp;Xiyang Zhong ,&nbsp;Ping Wang ,&nbsp;Yupeng Liu ,&nbsp;Siquan Li ,&nbsp;Wei Qin ,&nbsp;Sidun Fang","doi":"10.1016/j.jpowsour.2025.236823","DOIUrl":null,"url":null,"abstract":"<div><div>The dynamic electrochemical impedance spectra of a battery are more reflective of its real state under charging and discharging conditions than its static impedance spectra. However, the traditional sinusoidal sweep excitation signal greatly impedes the acquisition of low-frequency impedance and barely meets the “stability” test conditions under dynamic conditions during the charging and discharging of batteries. Thus, the low-frequency data of the current DEIS do not have reference value. This paper proposes a DEIS accelerated test method with the sampling function (Sa(t) signal) as the excitation signal, which utilizes the rectangular window spectral characteristics of the Sa(t) signal with uniform energy distribution over a wide frequency range, and realizes the acceleration of low-frequency impedance test under the premise of guaranteeing the test accuracy. To satisfy the requirements of rapid impedance spectroscopy in a frequency band from 1 kHz to 0.05 Hz, we propose a novel excitation signal by combining a sinusoidal sweep signal and two signals with different parameters Sa(t). Measurements of A123's 26,650 battery under 0.6C discharge conditions show that the DEIS of the battery from 1 kHz to 0.05 Hz can be obtained in 95 s. The test speed of low-frequency impedance has been improved by 92.13 % compared with the traditional frequency sweep method, the modulus error is less than 0.32 mΩ, and the phase error is less than 1.87°. This method solves the problem of the traditional swept excitation not being able to realize DEIS measurement because of the low efficiency of the low-frequency impedance test.</div></div>","PeriodicalId":377,"journal":{"name":"Journal of Power Sources","volume":"641 ","pages":"Article 236823"},"PeriodicalIF":8.1000,"publicationDate":"2025-03-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Power Sources","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0378775325006597","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, PHYSICAL","Score":null,"Total":0}
引用次数: 0

Abstract

The dynamic electrochemical impedance spectra of a battery are more reflective of its real state under charging and discharging conditions than its static impedance spectra. However, the traditional sinusoidal sweep excitation signal greatly impedes the acquisition of low-frequency impedance and barely meets the “stability” test conditions under dynamic conditions during the charging and discharging of batteries. Thus, the low-frequency data of the current DEIS do not have reference value. This paper proposes a DEIS accelerated test method with the sampling function (Sa(t) signal) as the excitation signal, which utilizes the rectangular window spectral characteristics of the Sa(t) signal with uniform energy distribution over a wide frequency range, and realizes the acceleration of low-frequency impedance test under the premise of guaranteeing the test accuracy. To satisfy the requirements of rapid impedance spectroscopy in a frequency band from 1 kHz to 0.05 Hz, we propose a novel excitation signal by combining a sinusoidal sweep signal and two signals with different parameters Sa(t). Measurements of A123's 26,650 battery under 0.6C discharge conditions show that the DEIS of the battery from 1 kHz to 0.05 Hz can be obtained in 95 s. The test speed of low-frequency impedance has been improved by 92.13 % compared with the traditional frequency sweep method, the modulus error is less than 0.32 mΩ, and the phase error is less than 1.87°. This method solves the problem of the traditional swept excitation not being able to realize DEIS measurement because of the low efficiency of the low-frequency impedance test.
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Power Sources
Journal of Power Sources 工程技术-电化学
CiteScore
16.40
自引率
6.50%
发文量
1249
审稿时长
36 days
期刊介绍: The Journal of Power Sources is a publication catering to researchers and technologists interested in various aspects of the science, technology, and applications of electrochemical power sources. It covers original research and reviews on primary and secondary batteries, fuel cells, supercapacitors, and photo-electrochemical cells. Topics considered include the research, development and applications of nanomaterials and novel componentry for these devices. Examples of applications of these electrochemical power sources include: • Portable electronics • Electric and Hybrid Electric Vehicles • Uninterruptible Power Supply (UPS) systems • Storage of renewable energy • Satellites and deep space probes • Boats and ships, drones and aircrafts • Wearable energy storage systems
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信