Efficacy and Safety of Accelerated Transepithelial Corneal Crosslinking in Non-Pediatric Patients with Progressive Keratoconus: Insights from a Retrospective Cohort Study.

IF 2.4 4区 医学 Q2 HEALTH CARE SCIENCES & SERVICES
Alina-Cristina Chiraples, Mihnea Munteanu, Horia T Stanca, Diana-Maria Darabus, Diana Barakat, Alina-Gabriela Negru
{"title":"Efficacy and Safety of Accelerated Transepithelial Corneal Crosslinking in Non-Pediatric Patients with Progressive Keratoconus: Insights from a Retrospective Cohort Study.","authors":"Alina-Cristina Chiraples, Mihnea Munteanu, Horia T Stanca, Diana-Maria Darabus, Diana Barakat, Alina-Gabriela Negru","doi":"10.3390/healthcare13050567","DOIUrl":null,"url":null,"abstract":"<p><strong>Background/objectives: </strong>Transepithelial accelerated corneal crosslinking (TE-ACXL) is a minimally invasive approach for stabilizing progressive keratoconus while preserving the corneal epithelium. This study aims to evaluate changes in visual acuity, refractive error, and corneal parameters before and six months after TE-ACXL.</p><p><strong>Methods: </strong>A retrospective analysis was conducted on 30 eyes from 20 patients who underwent TE-ACXL between May 2021 and June 2023. Variables included were uncorrected distance visual acuity (UDVA) and corrected distance visual acuity (CDVA), spherical and cylindrical refractive error, and corneal tomography parameters such as maximum keratometry (Kmax), the symmetry index (Si), the keratoconus vertex (KV), Baiocchi-Calossi-Versaci index (BCV), thinnest corneal thickness (TCT), and central corneal thickness (CCT).</p><p><strong>Results: </strong>CDVA improved from 0.20 ± 0.22 to 0.06 ± 0.11 LogMAR (<i>p</i> = 0.004), while UDVA improved from 0.47 ± 0.35 to 0.29 ± 0.30 LogMAR (<i>p</i> < 0.001). Spherical and cylindrical refractive error showed significant reductions from -2.18 ± 3.05 D to -1.31 ± 1.84 D (<i>p</i> < 0.001) and -3.33 ± 1.98 D to -2.33 ± 1.52 D (<i>p</i> < 0.001), respectively. Pachymetry values decreased significantly, with TCT reducing from 466.43 ± 31.24 µm to 438.63 ± 30.54 µm (<i>p</i> < 0.001) and CCT from 480.80 ± 33.24 µm to 451.23 ± 29.26 µm (<i>p</i> < 0.001). Kmax showed a modest reduction (52.33 ± 3.51 D to 51.19 ± 3.63 D, <i>p</i> < 0.001), while other topographic indices, including Si, KV, and BCV, exhibited minor, non-significant changes, except for BCV back (<i>p</i> = 0.031).</p><p><strong>Conclusions: </strong>TE-ACXL was associated with significant improvements in visual acuity and refractive stability at six months postoperatively while maintaining a favorable safety profile. The procedure may serve as an effective option for early intervention in progressive keratoconus.</p>","PeriodicalId":12977,"journal":{"name":"Healthcare","volume":"13 5","pages":""},"PeriodicalIF":2.4000,"publicationDate":"2025-03-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11899271/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Healthcare","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3390/healthcare13050567","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"HEALTH CARE SCIENCES & SERVICES","Score":null,"Total":0}
引用次数: 0

Abstract

Background/objectives: Transepithelial accelerated corneal crosslinking (TE-ACXL) is a minimally invasive approach for stabilizing progressive keratoconus while preserving the corneal epithelium. This study aims to evaluate changes in visual acuity, refractive error, and corneal parameters before and six months after TE-ACXL.

Methods: A retrospective analysis was conducted on 30 eyes from 20 patients who underwent TE-ACXL between May 2021 and June 2023. Variables included were uncorrected distance visual acuity (UDVA) and corrected distance visual acuity (CDVA), spherical and cylindrical refractive error, and corneal tomography parameters such as maximum keratometry (Kmax), the symmetry index (Si), the keratoconus vertex (KV), Baiocchi-Calossi-Versaci index (BCV), thinnest corneal thickness (TCT), and central corneal thickness (CCT).

Results: CDVA improved from 0.20 ± 0.22 to 0.06 ± 0.11 LogMAR (p = 0.004), while UDVA improved from 0.47 ± 0.35 to 0.29 ± 0.30 LogMAR (p < 0.001). Spherical and cylindrical refractive error showed significant reductions from -2.18 ± 3.05 D to -1.31 ± 1.84 D (p < 0.001) and -3.33 ± 1.98 D to -2.33 ± 1.52 D (p < 0.001), respectively. Pachymetry values decreased significantly, with TCT reducing from 466.43 ± 31.24 µm to 438.63 ± 30.54 µm (p < 0.001) and CCT from 480.80 ± 33.24 µm to 451.23 ± 29.26 µm (p < 0.001). Kmax showed a modest reduction (52.33 ± 3.51 D to 51.19 ± 3.63 D, p < 0.001), while other topographic indices, including Si, KV, and BCV, exhibited minor, non-significant changes, except for BCV back (p = 0.031).

Conclusions: TE-ACXL was associated with significant improvements in visual acuity and refractive stability at six months postoperatively while maintaining a favorable safety profile. The procedure may serve as an effective option for early intervention in progressive keratoconus.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Healthcare
Healthcare Medicine-Health Policy
CiteScore
3.50
自引率
7.10%
发文量
0
审稿时长
47 days
期刊介绍: Healthcare (ISSN 2227-9032) is an international, peer-reviewed, open access journal (free for readers), which publishes original theoretical and empirical work in the interdisciplinary area of all aspects of medicine and health care research. Healthcare publishes Original Research Articles, Reviews, Case Reports, Research Notes and Short Communications. We encourage researchers to publish their experimental and theoretical results in as much detail as possible. For theoretical papers, full details of proofs must be provided so that the results can be checked; for experimental papers, full experimental details must be provided so that the results can be reproduced. Additionally, electronic files or software regarding the full details of the calculations, experimental procedure, etc., can be deposited along with the publication as “Supplementary Material”.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信