Assessing the Fluctuation of Indoor Thermal Conditions in Naturally Ventilated Classrooms Through K-Means Clustering

IF 4.3 2区 环境科学与生态学 Q1 CONSTRUCTION & BUILDING TECHNOLOGY
Indoor air Pub Date : 2025-03-11 DOI:10.1155/ina/4453536
Sen Miao, Marta Gangolells, Blanca Tejedor
{"title":"Assessing the Fluctuation of Indoor Thermal Conditions in Naturally Ventilated Classrooms Through K-Means Clustering","authors":"Sen Miao,&nbsp;Marta Gangolells,&nbsp;Blanca Tejedor","doi":"10.1155/ina/4453536","DOIUrl":null,"url":null,"abstract":"<p>For naturally ventilated classrooms, windows should be constantly open to maintain good indoor air quality during class times. However, it is unknown whether this would result in significant fluctuations in the indoor thermal environment, while the effects of ventilation rate and window operation are still unclear. Therefore, this study assesses the fluctuation of indoor thermal conditions under natural ventilation during class periods, based on the <i>K</i>-means clustering and statistical analysis of data collected in a large measurement campaign in Spanish schools. The results showed that regardless of the heating mode, the indoor thermal parameters remained stable in most cases. High fluctuations were observed only in a few cases: 15% for indoor temperature, 6% for relative humidity, and 3% for indoor air velocity. The variability of the indoor thermal parameters within an hour was less than 1°C for indoor temperature, 3% for relative humidity, and 0.1 m/s for indoor air velocity. Ventilation rate and window operation were found to be related to the fluctuation of the indoor temperature and air velocity, rather than the relative humidity. These findings shed light on the thermal conditions in naturally ventilated classrooms and have practical implications for the implementation of natural ventilation protocols in schools.</p>","PeriodicalId":13529,"journal":{"name":"Indoor air","volume":"2025 1","pages":""},"PeriodicalIF":4.3000,"publicationDate":"2025-03-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1155/ina/4453536","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Indoor air","FirstCategoryId":"93","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1155/ina/4453536","RegionNum":2,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CONSTRUCTION & BUILDING TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

For naturally ventilated classrooms, windows should be constantly open to maintain good indoor air quality during class times. However, it is unknown whether this would result in significant fluctuations in the indoor thermal environment, while the effects of ventilation rate and window operation are still unclear. Therefore, this study assesses the fluctuation of indoor thermal conditions under natural ventilation during class periods, based on the K-means clustering and statistical analysis of data collected in a large measurement campaign in Spanish schools. The results showed that regardless of the heating mode, the indoor thermal parameters remained stable in most cases. High fluctuations were observed only in a few cases: 15% for indoor temperature, 6% for relative humidity, and 3% for indoor air velocity. The variability of the indoor thermal parameters within an hour was less than 1°C for indoor temperature, 3% for relative humidity, and 0.1 m/s for indoor air velocity. Ventilation rate and window operation were found to be related to the fluctuation of the indoor temperature and air velocity, rather than the relative humidity. These findings shed light on the thermal conditions in naturally ventilated classrooms and have practical implications for the implementation of natural ventilation protocols in schools.

Abstract Image

基于k均值聚类的自然通风教室室内热条件波动评估
对于自然通风的教室,在上课时间应经常打开窗户,以保持良好的室内空气质量。然而,这是否会导致室内热环境的显著波动尚不清楚,而通风量和开窗的影响尚不清楚。因此,本研究基于k均值聚类和对西班牙学校大规模测量活动中收集的数据的统计分析,评估了课堂期间自然通风下室内热条件的波动。结果表明,无论采用何种采暖方式,室内热参数在大多数情况下保持稳定。只有在少数情况下观察到高波动:室内温度为15%,相对湿度为6%,室内空气速度为3%。室内热参数在1小时内的变异性为:室内温度小于1℃,相对湿度小于3%,室内风速小于0.1 m/s。通风量和开窗次数与室内温度和风速的波动有关,而与相对湿度无关。这些发现揭示了自然通风教室的热条件,并对学校自然通风协议的实施具有实际意义。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Indoor air
Indoor air 环境科学-工程:环境
CiteScore
10.80
自引率
10.30%
发文量
175
审稿时长
3 months
期刊介绍: The quality of the environment within buildings is a topic of major importance for public health. Indoor Air provides a location for reporting original research results in the broad area defined by the indoor environment of non-industrial buildings. An international journal with multidisciplinary content, Indoor Air publishes papers reflecting the broad categories of interest in this field: health effects; thermal comfort; monitoring and modelling; source characterization; ventilation and other environmental control techniques. The research results present the basic information to allow designers, building owners, and operators to provide a healthy and comfortable environment for building occupants, as well as giving medical practitioners information on how to deal with illnesses related to the indoor environment.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信