The Endolymph Signal in Non-contrast Enhanced 3D-real IR Image Differs between the Ears with and without Significant Endolymphatic Hydrops.

Shinji Naganawa, Rintaro Ito, Mariko Kawamura, Toshiaki Taoka, Tadao Yoshida, Michihiko Sone
{"title":"The Endolymph Signal in Non-contrast Enhanced 3D-real IR Image Differs between the Ears with and without Significant Endolymphatic Hydrops.","authors":"Shinji Naganawa, Rintaro Ito, Mariko Kawamura, Toshiaki Taoka, Tadao Yoshida, Michihiko Sone","doi":"10.2463/mrms.mp.2024-0191","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To investigate whether significant differences exist in labyrinthine lymph fluid signal intensities on non-contrast-enhanced 3D real inversion recovery (3D-real IR) images between patients with and without significant endolymphatic hydrops (EH), potentially enabling the non-contrast detection of EH.</p><p><strong>Methods: </strong>Thirty-nine patients suspected of having EH underwent 3D-real IR MRI before and 4 hours after intravenous administration of a single dose of gadobutrol. Signal intensities of the cerebrospinal fluid (CSF), perilymph, and endolymph were manually measured on pre-contrast images using ROIs. Patients were categorized into 2 groups based on post-contrast imaging: those with significant EH and those without. Normalized signal intensities (nSIs) of the endolymph were calculated and compared between the groups using the Mann-Whitney U test.</p><p><strong>Results: </strong>The nSIs of the vestibular endolymph on non-contrast 3D-real IR images were significantly lower in the group with significant EH compared to the group without EH (P  < 0.05), suggesting T1 prolongation in the vestibular endolymph of patients with significant EH. However, considerable overlap was observed in the nSIs between the 2 groups, and significant EH did not always result in T1 prolongation. No significant differences were found in the nSIs of the perilymph or CSF between the groups.</p><p><strong>Conclusion: </strong>The study suggests that T1 prolongation occurs in the vestibular endolymph in cases of significant EH. This finding indicates the potential for developing non-contrast MRI methods to detect EH and underscores the importance of understanding the mechanisms behind T1 changes in the endolymph. Further research with larger patient cohorts and inclusion of healthy control subjects is necessary to validate these results and to elucidate the pathophysiology of EH in Ménière's disease.</p>","PeriodicalId":94126,"journal":{"name":"Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2025-03-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2463/mrms.mp.2024-0191","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To investigate whether significant differences exist in labyrinthine lymph fluid signal intensities on non-contrast-enhanced 3D real inversion recovery (3D-real IR) images between patients with and without significant endolymphatic hydrops (EH), potentially enabling the non-contrast detection of EH.

Methods: Thirty-nine patients suspected of having EH underwent 3D-real IR MRI before and 4 hours after intravenous administration of a single dose of gadobutrol. Signal intensities of the cerebrospinal fluid (CSF), perilymph, and endolymph were manually measured on pre-contrast images using ROIs. Patients were categorized into 2 groups based on post-contrast imaging: those with significant EH and those without. Normalized signal intensities (nSIs) of the endolymph were calculated and compared between the groups using the Mann-Whitney U test.

Results: The nSIs of the vestibular endolymph on non-contrast 3D-real IR images were significantly lower in the group with significant EH compared to the group without EH (P  < 0.05), suggesting T1 prolongation in the vestibular endolymph of patients with significant EH. However, considerable overlap was observed in the nSIs between the 2 groups, and significant EH did not always result in T1 prolongation. No significant differences were found in the nSIs of the perilymph or CSF between the groups.

Conclusion: The study suggests that T1 prolongation occurs in the vestibular endolymph in cases of significant EH. This finding indicates the potential for developing non-contrast MRI methods to detect EH and underscores the importance of understanding the mechanisms behind T1 changes in the endolymph. Further research with larger patient cohorts and inclusion of healthy control subjects is necessary to validate these results and to elucidate the pathophysiology of EH in Ménière's disease.

非对比增强3d真实红外图像的内淋巴信号在有和没有明显内淋巴水肿的耳朵之间是不同的。
目的:探讨有无明显内淋巴水肿(EH)患者迷路淋巴液信号在非对比增强3D真实反转恢复(3D-real IR)图像上是否存在显著差异,为EH的非对比检测提供可能。方法:39例疑似EH患者在单次静脉给药加多布洛前和给药后4小时行3D-real IR MRI检查。使用roi在对比前图像上手动测量脑脊液(CSF)、淋巴周围和淋巴内的信号强度。根据对比后成像将患者分为两组:有明显EH和无明显EH的患者。采用Mann-Whitney U检验计算各组间内淋巴归一化信号强度(nsi)。结果:EH明显组前庭内淋巴非对比3D-real IR成像nsi明显低于未见EH组(P )结论:研究提示EH明显组前庭内淋巴T1延长。这一发现表明了发展非对比MRI方法检测EH的潜力,并强调了了解内淋巴T1变化背后机制的重要性。有必要在更大的患者队列中进行进一步的研究,并纳入健康对照受试者,以验证这些结果,并阐明在mims中EH的病理生理学。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信