Successful removal of a large intratracheal tumor using the injection-time-controllable manual jet ventilator via translaryngeal approach-a case report.

IF 4.2 4区 医学 Q1 ANESTHESIOLOGY
Darhae Eum, Hyun Joo Kim, Wyun Kon Park
{"title":"Successful removal of a large intratracheal tumor using the injection-time-controllable manual jet ventilator via translaryngeal approach-a case report.","authors":"Darhae Eum, Hyun Joo Kim, Wyun Kon Park","doi":"10.4097/kja.24918","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Removal of intratracheal tumors is challenging due to the difficulty in securing a patent airway before surgery. We report a case of successful removal using jet ventilation with an injection-time-controllable manual jet ventilator.</p><p><strong>Case: </strong>A 3.3 cm long intratracheal mass was located 5 cm below the vocal cords and obstructing 70-80% of the trachea. Following induction, a rigid telescope under suspension laryngoscopy was used to guide the careful insertion of a hard and long catheter (inner diameter: 1.8 mm; outer diameter: 3 mm; length: 50 cm) beyond the tumor, enabling jet ventilation. The soft, lobulated mass was gradually excised using long forceps under endoscopic visualization. Anesthesia was maintained using total intravenous anesthesia. The operation lasted for 1 h and 45 min.</p><p><strong>Conclusions: </strong>This device ensured oxygenation and ventilation during the endoscopic removal of a large intratracheal tumor. This approach highlights its utility in managing challenging airway obstructions.</p>","PeriodicalId":17855,"journal":{"name":"Korean Journal of Anesthesiology","volume":" ","pages":""},"PeriodicalIF":4.2000,"publicationDate":"2025-03-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Korean Journal of Anesthesiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.4097/kja.24918","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ANESTHESIOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Removal of intratracheal tumors is challenging due to the difficulty in securing a patent airway before surgery. We report a case of successful removal using jet ventilation with an injection-time-controllable manual jet ventilator.

Case: A 3.3 cm long intratracheal mass was located 5 cm below the vocal cords and obstructing 70-80% of the trachea. Following induction, a rigid telescope under suspension laryngoscopy was used to guide the careful insertion of a hard and long catheter (inner diameter: 1.8 mm; outer diameter: 3 mm; length: 50 cm) beyond the tumor, enabling jet ventilation. The soft, lobulated mass was gradually excised using long forceps under endoscopic visualization. Anesthesia was maintained using total intravenous anesthesia. The operation lasted for 1 h and 45 min.

Conclusions: This device ensured oxygenation and ventilation during the endoscopic removal of a large intratracheal tumor. This approach highlights its utility in managing challenging airway obstructions.

求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
6.20
自引率
6.90%
发文量
84
审稿时长
16 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信