Single-electrode electrochemiluminescence immunoarray combined with smartphone for high-throughput detection of heart-type fatty acid binding protein

IF 4.9 2区 化学 Q1 CHEMISTRY, ANALYTICAL
Mingquan Guo , Yifeng Pan , Dexin Du , Liangbiao Wang , Wei Nie
{"title":"Single-electrode electrochemiluminescence immunoarray combined with smartphone for high-throughput detection of heart-type fatty acid binding protein","authors":"Mingquan Guo ,&nbsp;Yifeng Pan ,&nbsp;Dexin Du ,&nbsp;Liangbiao Wang ,&nbsp;Wei Nie","doi":"10.1016/j.microc.2025.113249","DOIUrl":null,"url":null,"abstract":"<div><div>Acute myocardial infarction (AMI) is a cardiovascular disease with high fatality and acute morbidity. The timely diagnosis and treatment are vital for improving recovery of AMI patients. Heart-type fatty acid binding protein (h-FABP) is an important biomarker for early assessment and exclusion of AMI. Herein, we developed single-electrode electrochemiluminescence (ECL) immunoarray for high throughput and portable detection of h-FABP. This ECL immunoarray was fabricated by successively assembling ECL nanocomposites and h-FABP conjugated gold nanoparticles on the surface of indium tin oxide microchips electrodes and the bovine serum albumin was used in blocking nonspecific binding sites, which can be used for detection of h-FABP. In the presence of h-FABP, the ECL intensity increased with increasing concentration. Thus, a high throughput and portable immunoarray was established for the determination of h-FABP with a linear dynamic range from 0.1 to 1000 pg/mL and a detection limit of 0.09 pg/mL, which exhibited excellent performance compared with other ECL methods. Moreover, the developed ECL immunoarray was used in detecting the h-FABP in clinical sample of human serum, which demonstrated good recoveries in the range of 92.20 %∼108.00 %. Therefore, the proposed ECL immunoarray can effectively handle the determination of clinical samples, which was promising for using the early screening or exclusion for AMI at home or in an ambulance due to portable detection based on smartphone. This strategy is very promising to effectively reduce fatality and acute morbidity of AMI patients.</div></div>","PeriodicalId":391,"journal":{"name":"Microchemical Journal","volume":"212 ","pages":"Article 113249"},"PeriodicalIF":4.9000,"publicationDate":"2025-03-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Microchemical Journal","FirstCategoryId":"92","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0026265X25006034","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Acute myocardial infarction (AMI) is a cardiovascular disease with high fatality and acute morbidity. The timely diagnosis and treatment are vital for improving recovery of AMI patients. Heart-type fatty acid binding protein (h-FABP) is an important biomarker for early assessment and exclusion of AMI. Herein, we developed single-electrode electrochemiluminescence (ECL) immunoarray for high throughput and portable detection of h-FABP. This ECL immunoarray was fabricated by successively assembling ECL nanocomposites and h-FABP conjugated gold nanoparticles on the surface of indium tin oxide microchips electrodes and the bovine serum albumin was used in blocking nonspecific binding sites, which can be used for detection of h-FABP. In the presence of h-FABP, the ECL intensity increased with increasing concentration. Thus, a high throughput and portable immunoarray was established for the determination of h-FABP with a linear dynamic range from 0.1 to 1000 pg/mL and a detection limit of 0.09 pg/mL, which exhibited excellent performance compared with other ECL methods. Moreover, the developed ECL immunoarray was used in detecting the h-FABP in clinical sample of human serum, which demonstrated good recoveries in the range of 92.20 %∼108.00 %. Therefore, the proposed ECL immunoarray can effectively handle the determination of clinical samples, which was promising for using the early screening or exclusion for AMI at home or in an ambulance due to portable detection based on smartphone. This strategy is very promising to effectively reduce fatality and acute morbidity of AMI patients.

Abstract Image

求助全文
约1分钟内获得全文 求助全文
来源期刊
Microchemical Journal
Microchemical Journal 化学-分析化学
CiteScore
8.70
自引率
8.30%
发文量
1131
审稿时长
1.9 months
期刊介绍: The Microchemical Journal is a peer reviewed journal devoted to all aspects and phases of analytical chemistry and chemical analysis. The Microchemical Journal publishes articles which are at the forefront of modern analytical chemistry and cover innovations in the techniques to the finest possible limits. This includes fundamental aspects, instrumentation, new developments, innovative and novel methods and applications including environmental and clinical field. Traditional classical analytical methods such as spectrophotometry and titrimetry as well as established instrumentation methods such as flame and graphite furnace atomic absorption spectrometry, gas chromatography, and modified glassy or carbon electrode electrochemical methods will be considered, provided they show significant improvements and novelty compared to the established methods.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信