An approach to electroanatomical mapping with a pentaspline pulsed field catheter to guide atrial fibrillation ablation.

IF 2.1 4区 医学 Q3 CARDIAC & CARDIOVASCULAR SYSTEMS
Mark T Mills, Peter Calvert, Calum Phenton, Nicole Worthington, Derick Todd, Simon Modi, Reza Ashrafi, Richard Snowdon, Dhiraj Gupta, Vishal Luther
{"title":"An approach to electroanatomical mapping with a pentaspline pulsed field catheter to guide atrial fibrillation ablation.","authors":"Mark T Mills, Peter Calvert, Calum Phenton, Nicole Worthington, Derick Todd, Simon Modi, Reza Ashrafi, Richard Snowdon, Dhiraj Gupta, Vishal Luther","doi":"10.1007/s10840-025-01980-6","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Pulsed field ablation (PFA) of atrial fibrillation (AF) using a pentaspline multi-electrode catheter is commonly performed under fluoroscopic guidance. No data exist on the integration of this catheter within a three-dimensional electroanatomical mapping (3D-EAM) system for left atrial voltage and activation mapping, posterior wall isolation (PWI), or redo ablation. This technical report reviews an approach whereby mapping is performed using the pentaspline PFA catheter itself within an open architectural impedance-based 3D-EAM system.</p><p><strong>Methods: </strong>Cases involved mapping with the PFA catheter itself, with real-time visualisation of the guidewire tip and catheter within the 3D-EAM system. In certain cases, additional 3D-EAM was performed with a grid-style high-density mapping catheter for comparison.</p><p><strong>Results: </strong>In a series of 22 patients (45% female, mean age 63 ± 13 years, 55% paroxysmal AF, 27% redo procedures), mapping increased procedural times (mean 108 min vs. 68 min in fluoroscopy-only controls), without reducing fluoroscopy times. Three potential advantages of mapping with the PFA catheter were identified: (1) The technique helped identify sleeves of incomplete pulmonary vein isolation after index applications. (2) In the four cases mapped with both the PFA and grid-style catheters, voltage maps appeared concordant. (3) The technique helped facilitate robust PWI and identify inadvertent partial PWI.</p><p><strong>Conclusions: </strong>3D-EAM with a pentaspline PFA catheter itself is feasible, without the need for high-density mapping catheters. This approach has potential advantages over fluoroscopic-only guidance, although its long-term efficacy and cost-effectiveness require formal assessment.</p>","PeriodicalId":16202,"journal":{"name":"Journal of Interventional Cardiac Electrophysiology","volume":" ","pages":""},"PeriodicalIF":2.1000,"publicationDate":"2025-03-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Interventional Cardiac Electrophysiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s10840-025-01980-6","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Pulsed field ablation (PFA) of atrial fibrillation (AF) using a pentaspline multi-electrode catheter is commonly performed under fluoroscopic guidance. No data exist on the integration of this catheter within a three-dimensional electroanatomical mapping (3D-EAM) system for left atrial voltage and activation mapping, posterior wall isolation (PWI), or redo ablation. This technical report reviews an approach whereby mapping is performed using the pentaspline PFA catheter itself within an open architectural impedance-based 3D-EAM system.

Methods: Cases involved mapping with the PFA catheter itself, with real-time visualisation of the guidewire tip and catheter within the 3D-EAM system. In certain cases, additional 3D-EAM was performed with a grid-style high-density mapping catheter for comparison.

Results: In a series of 22 patients (45% female, mean age 63 ± 13 years, 55% paroxysmal AF, 27% redo procedures), mapping increased procedural times (mean 108 min vs. 68 min in fluoroscopy-only controls), without reducing fluoroscopy times. Three potential advantages of mapping with the PFA catheter were identified: (1) The technique helped identify sleeves of incomplete pulmonary vein isolation after index applications. (2) In the four cases mapped with both the PFA and grid-style catheters, voltage maps appeared concordant. (3) The technique helped facilitate robust PWI and identify inadvertent partial PWI.

Conclusions: 3D-EAM with a pentaspline PFA catheter itself is feasible, without the need for high-density mapping catheters. This approach has potential advantages over fluoroscopic-only guidance, although its long-term efficacy and cost-effectiveness require formal assessment.

求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
4.30
自引率
11.10%
发文量
320
审稿时长
4-8 weeks
期刊介绍: The Journal of Interventional Cardiac Electrophysiology is an international publication devoted to fostering research in and development of interventional techniques and therapies for the management of cardiac arrhythmias. It is designed primarily to present original research studies and scholarly scientific reviews of basic and applied science and clinical research in this field. The Journal will adopt a multidisciplinary approach to link physical, experimental, and clinical sciences as applied to the development of and practice in interventional electrophysiology. The Journal will examine techniques ranging from molecular, chemical and pharmacologic therapies to device and ablation technology. Accordingly, original research in clinical, epidemiologic and basic science arenas will be considered for publication. Applied engineering or physical science studies pertaining to interventional electrophysiology will be encouraged. The Journal is committed to providing comprehensive and detailed treatment of major interventional therapies and innovative techniques in a structured and clinically relevant manner. It is directed at clinical practitioners and investigators in the rapidly growing field of interventional electrophysiology. The editorial staff and board reflect this bias and include noted international experts in this area with a wealth of expertise in basic and clinical investigation. Peer review of all submissions, conflict of interest guidelines and periodic editorial board review of all Journal policies have been established.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信