Novel Bronchoscopy Method for Molecular Profiling of Lung Cancer: Targeted Washing Technique.

IF 4.1 2区 医学 Q2 ONCOLOGY
Mi-Hyun Kim, Hayoung Seong, Hyojin Jang, Saerom Kim, Wanho Yoo, Soo Han Kim, Jeongha Mok, Kwangha Lee, Ki Uk Kim, Min Ki Lee, Jung Seop Eom
{"title":"Novel Bronchoscopy Method for Molecular Profiling of Lung Cancer: Targeted Washing Technique.","authors":"Mi-Hyun Kim, Hayoung Seong, Hyojin Jang, Saerom Kim, Wanho Yoo, Soo Han Kim, Jeongha Mok, Kwangha Lee, Ki Uk Kim, Min Ki Lee, Jung Seop Eom","doi":"10.4143/crt.2024.1128","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>There have been efforts to find alternative samples other than standard samples of tissue or plasma for mutational analyses for lung cancer patients. However, no other sample or technique has replaced the mutational analyses using standard samples. In this prospective study, we assessed a novel bronchoscopy method, named as targeted washing technique, for detecting the EGFR mutation.</p><p><strong>Materials and methods: </strong>A 3.0-mm ultrathin bronchoscope was precisely navigated to the target lung lesion with the assistance of virtual bronchoscopic navigation and fluoroscopy. Once the bronchoscope is placed in front of target lung lesion, 0.9% normal saline was instilled for targeted washing. EGFR testing using targeted washing fluid (TWF) was compared to standard methods using plasma or tumor tissue.</p><p><strong>Results: </strong>In 41 TWF samples, the T790M mutation was detected in tissue, plasma, and TWF samples at rates of 22%, 10%, and 29%, respectively. The overall EGFR T790M detection rate using tissue, plasma, or TWF samples was 37%, with TWF samples increasing the T790M mutation detection rate by up to 10%. The accuracy of T790M mutation detection using TWF sample was 83% compared with standard samples. Four patients were found to have the EGFR T790M mutation solely through EGFR testing using TWF, which repeated rebiopsies using either plasma or tissue finally confirmed to have the T790M mutation.</p><p><strong>Conclusion: </strong>We demonstrated the clinical potential of targeted washing technique for molecular testing, which can be a good option to overcome spatial heterogeneity, low sensitivity of plasma sample or technical limitations in collecting tumor tissues.</p>","PeriodicalId":49094,"journal":{"name":"Cancer Research and Treatment","volume":" ","pages":""},"PeriodicalIF":4.1000,"publicationDate":"2025-02-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cancer Research and Treatment","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.4143/crt.2024.1128","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ONCOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: There have been efforts to find alternative samples other than standard samples of tissue or plasma for mutational analyses for lung cancer patients. However, no other sample or technique has replaced the mutational analyses using standard samples. In this prospective study, we assessed a novel bronchoscopy method, named as targeted washing technique, for detecting the EGFR mutation.

Materials and methods: A 3.0-mm ultrathin bronchoscope was precisely navigated to the target lung lesion with the assistance of virtual bronchoscopic navigation and fluoroscopy. Once the bronchoscope is placed in front of target lung lesion, 0.9% normal saline was instilled for targeted washing. EGFR testing using targeted washing fluid (TWF) was compared to standard methods using plasma or tumor tissue.

Results: In 41 TWF samples, the T790M mutation was detected in tissue, plasma, and TWF samples at rates of 22%, 10%, and 29%, respectively. The overall EGFR T790M detection rate using tissue, plasma, or TWF samples was 37%, with TWF samples increasing the T790M mutation detection rate by up to 10%. The accuracy of T790M mutation detection using TWF sample was 83% compared with standard samples. Four patients were found to have the EGFR T790M mutation solely through EGFR testing using TWF, which repeated rebiopsies using either plasma or tissue finally confirmed to have the T790M mutation.

Conclusion: We demonstrated the clinical potential of targeted washing technique for molecular testing, which can be a good option to overcome spatial heterogeneity, low sensitivity of plasma sample or technical limitations in collecting tumor tissues.

求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
8.00
自引率
2.20%
发文量
126
审稿时长
>12 weeks
期刊介绍: Cancer Research and Treatment is a peer-reviewed open access publication of the Korean Cancer Association. It is published quarterly, one volume per year. Abbreviated title is Cancer Res Treat. It accepts manuscripts relevant to experimental and clinical cancer research. Subjects include carcinogenesis, tumor biology, molecular oncology, cancer genetics, tumor immunology, epidemiology, predictive markers and cancer prevention, pathology, cancer diagnosis, screening and therapies including chemotherapy, surgery, radiation therapy, immunotherapy, gene therapy, multimodality treatment and palliative care.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信