Comparison of two different intraocular lenses used in the modified Yamane technique.

IF 2.1 4区 医学 Q2 OPHTHALMOLOGY
Indian Journal of Ophthalmology Pub Date : 2025-03-01 Epub Date: 2025-02-26 DOI:10.4103/IJO.IJO_2235_24
Fahri O Aydin, Burakhan K Aksoy, Ali Ceylan, Yusuf B Akbaş, Murat Karapapak, Burçin Kepez Yildiz, Yusuf Yildirim
{"title":"Comparison of two different intraocular lenses used in the modified Yamane technique.","authors":"Fahri O Aydin, Burakhan K Aksoy, Ali Ceylan, Yusuf B Akbaş, Murat Karapapak, Burçin Kepez Yildiz, Yusuf Yildirim","doi":"10.4103/IJO.IJO_2235_24","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To compare AcrySof MA60AC (Alcon Laboratories, Fort Worth, TX, USA) and Sensar AR40e (Johnson and Johnson, Santa Ana, CA, USA) used in Yamane sutureless scleral fixation technique in terms of visual acuity, refractive stability, and complications.</p><p><strong>Methods: </strong>A retrospective, cross-sectional study was conducted in Istanbul Başakşehir Çam and Sakura City Hospital. Patients were divided into two groups: The first group consisted of patients with MA60AC lenses, while the second group consisted of patients with AR40e. Aphakic patients who underwent secondary intraocular lens (IOL) implantation and had postoperative minimum 3-month follow-up records were included. Visual acuity, refractive outcomes, perioperative and postoperative complications were recorded.</p><p><strong>Results: </strong>Forty-nine patients were included in the study. Twenty-two patients were in the first group and 27 patients were in the second group. Age, gender, and follow-up time were similar between groups (P = 0.546, 0.213, and 0.347, respectively). The median lenticular astigmatism value was 0.86 (0.08-2.11) D in group 1 and 0.99 (0.31-2.96) D in group 2 (P = 0.898). There was no significant difference between groups in terms of visual acuity, spherical, cylindrical, and spherical equivalent values (P = 0.752, 0.375, 0.073, and 0.949, respectively). In group 1, a haptic tip fracture and optic-haptic separation were observed perioperatively. Optic-haptic junction separation was observed in one patient in group 1 on postoperative day 1. In group 1, epiretinal membrane development was significantly higher (P = 0.019).</p><p><strong>Conclusions: </strong>Both AcrySof MA60AC and Sensar AR40e IOLs via the modified Yamane technique yielded favorable and predictable outcomes. Although statistically insignificant, haptic problems were more common in the first group.</p>","PeriodicalId":13329,"journal":{"name":"Indian Journal of Ophthalmology","volume":"73 3","pages":"416-421"},"PeriodicalIF":2.1000,"publicationDate":"2025-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Indian Journal of Ophthalmology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.4103/IJO.IJO_2235_24","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/2/26 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To compare AcrySof MA60AC (Alcon Laboratories, Fort Worth, TX, USA) and Sensar AR40e (Johnson and Johnson, Santa Ana, CA, USA) used in Yamane sutureless scleral fixation technique in terms of visual acuity, refractive stability, and complications.

Methods: A retrospective, cross-sectional study was conducted in Istanbul Başakşehir Çam and Sakura City Hospital. Patients were divided into two groups: The first group consisted of patients with MA60AC lenses, while the second group consisted of patients with AR40e. Aphakic patients who underwent secondary intraocular lens (IOL) implantation and had postoperative minimum 3-month follow-up records were included. Visual acuity, refractive outcomes, perioperative and postoperative complications were recorded.

Results: Forty-nine patients were included in the study. Twenty-two patients were in the first group and 27 patients were in the second group. Age, gender, and follow-up time were similar between groups (P = 0.546, 0.213, and 0.347, respectively). The median lenticular astigmatism value was 0.86 (0.08-2.11) D in group 1 and 0.99 (0.31-2.96) D in group 2 (P = 0.898). There was no significant difference between groups in terms of visual acuity, spherical, cylindrical, and spherical equivalent values (P = 0.752, 0.375, 0.073, and 0.949, respectively). In group 1, a haptic tip fracture and optic-haptic separation were observed perioperatively. Optic-haptic junction separation was observed in one patient in group 1 on postoperative day 1. In group 1, epiretinal membrane development was significantly higher (P = 0.019).

Conclusions: Both AcrySof MA60AC and Sensar AR40e IOLs via the modified Yamane technique yielded favorable and predictable outcomes. Although statistically insignificant, haptic problems were more common in the first group.

求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
3.80
自引率
19.40%
发文量
1963
审稿时长
38 weeks
期刊介绍: Indian Journal of Ophthalmology covers clinical, experimental, basic science research and translational research studies related to medical, ethical and social issues in field of ophthalmology and vision science. Articles with clinical interest and implications will be given preference.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信