Short-term efficacy and safety of A-stream glaucoma shunt: a 6-month study.

IF 2.8 3区 医学 Q1 OPHTHALMOLOGY
Eye Pub Date : 2025-02-21 DOI:10.1038/s41433-025-03728-y
Hae Min Park, Eun Jung Lee, Jong Chul Han, Seungsoo Rho, Jong Hoon Shin, Do Young Park
{"title":"Short-term efficacy and safety of A-stream glaucoma shunt: a 6-month study.","authors":"Hae Min Park, Eun Jung Lee, Jong Chul Han, Seungsoo Rho, Jong Hoon Shin, Do Young Park","doi":"10.1038/s41433-025-03728-y","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>This study evaluated the short-term efficacy and safety of the A-stream Glaucoma Shunt (A-stream; MICROT Inc., Republic of Korea) in patients who completed 6 months of follow-up after implantation.</p><p><strong>Methods: </strong>Medical records of 49 patients (49 eyes) who underwent A-stream implantation between October 2023 and February 2024 were retrospectively reviewed. Primary outcomes included surgical success and intraocular pressure (IOP) reduction at 6 months postoperatively. Success was defined as achieving an IOP ≤ 18 mmHg, with at least a 20% reduction from preoperative IOP, and without clinically significant hypotony (IOP < 6 mmHg persisting >1 month or with hypotony maculopathy), classified as qualified (with or without medications) or complete (without medications). Ripcord removal timing and its effect on IOP, postoperative interventions, and complications were analysed.</p><p><strong>Results: </strong>At 6 months, the mean IOP significantly decreased from 26.9 ± 8.3 mmHg to 11.9 ± 3.5 mmHg (P < 0.01). Complete success was achieved in 77.6% and qualified success in 93.9% of the eyes. The ripcord was removed in 73.5% of eyes at an average of 1.8 ± 1.3 months postoperatively, which led to further IOP reduction of 6.8 ± 5.0 mmHg 1 month after removal. No cases of clinically significant hypotony or vision-threatening complications were observed.</p><p><strong>Conclusions: </strong>The A-stream demonstrated excellent short-term efficacy and safety in lowering IOP with high success rates. The ripcord enabled controlled IOP adjustments postoperatively. Further studies are warranted to evaluate long-term outcomes and compare them with conventional surgeries.</p>","PeriodicalId":12125,"journal":{"name":"Eye","volume":" ","pages":""},"PeriodicalIF":2.8000,"publicationDate":"2025-02-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Eye","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1038/s41433-025-03728-y","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: This study evaluated the short-term efficacy and safety of the A-stream Glaucoma Shunt (A-stream; MICROT Inc., Republic of Korea) in patients who completed 6 months of follow-up after implantation.

Methods: Medical records of 49 patients (49 eyes) who underwent A-stream implantation between October 2023 and February 2024 were retrospectively reviewed. Primary outcomes included surgical success and intraocular pressure (IOP) reduction at 6 months postoperatively. Success was defined as achieving an IOP ≤ 18 mmHg, with at least a 20% reduction from preoperative IOP, and without clinically significant hypotony (IOP < 6 mmHg persisting >1 month or with hypotony maculopathy), classified as qualified (with or without medications) or complete (without medications). Ripcord removal timing and its effect on IOP, postoperative interventions, and complications were analysed.

Results: At 6 months, the mean IOP significantly decreased from 26.9 ± 8.3 mmHg to 11.9 ± 3.5 mmHg (P < 0.01). Complete success was achieved in 77.6% and qualified success in 93.9% of the eyes. The ripcord was removed in 73.5% of eyes at an average of 1.8 ± 1.3 months postoperatively, which led to further IOP reduction of 6.8 ± 5.0 mmHg 1 month after removal. No cases of clinically significant hypotony or vision-threatening complications were observed.

Conclusions: The A-stream demonstrated excellent short-term efficacy and safety in lowering IOP with high success rates. The ripcord enabled controlled IOP adjustments postoperatively. Further studies are warranted to evaluate long-term outcomes and compare them with conventional surgeries.

A 流青光眼分流术的短期疗效和安全性:为期 6 个月的研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Eye
Eye 医学-眼科学
CiteScore
6.40
自引率
5.10%
发文量
481
审稿时长
3-6 weeks
期刊介绍: Eye seeks to provide the international practising ophthalmologist with high quality articles, of academic rigour, on the latest global clinical and laboratory based research. Its core aim is to advance the science and practice of ophthalmology with the latest clinical- and scientific-based research. Whilst principally aimed at the practising clinician, the journal contains material of interest to a wider readership including optometrists, orthoptists, other health care professionals and research workers in all aspects of the field of visual science worldwide. Eye is the official journal of The Royal College of Ophthalmologists. Eye encourages the submission of original articles covering all aspects of ophthalmology including: external eye disease; oculo-plastic surgery; orbital and lacrimal disease; ocular surface and corneal disorders; paediatric ophthalmology and strabismus; glaucoma; medical and surgical retina; neuro-ophthalmology; cataract and refractive surgery; ocular oncology; ophthalmic pathology; ophthalmic genetics.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信