Sternal Reconstruction with Titanium Prosthesis for Complicated Sternal Dehiscence with Right Ventricle Herniation after Cardiac Surgery: A Case Report.
Luís Alexandre Lourenço Graça, Rita Lopes, Carlos Branco, Rita Pancas
{"title":"Sternal Reconstruction with Titanium Prosthesis for Complicated Sternal Dehiscence with Right Ventricle Herniation after Cardiac Surgery: A Case Report.","authors":"Luís Alexandre Lourenço Graça, Rita Lopes, Carlos Branco, Rita Pancas","doi":"10.5090/jcs.24.087","DOIUrl":null,"url":null,"abstract":"<p><p>Sternal wound dehiscence after cardiac surgery is usually accompanied by a high morbidity and mortality rate. When sternal rewiring fails, rigid fixation systems may be used for sternal reconstruction. We report a case involving a female patient with multiple risk factors for sternal dehiscence who underwent a coronary artery bypass graft procedure. Postoperatively, she experienced sternal dehiscence that necessitated primary rewiring. Despite the surgical intervention and clinical optimization, the sternal wound dehiscence recurred. The patient experienced severe chest pain and thoracic instability, presenting with complete non-union of the sternal segments and right ventricular protrusion. Given the symptoms and the risk of both direct and indirect trauma to the heart, the multidisciplinary team opted to reinforce the anterior chest wall with a pre-planned titanium prosthesis to provide protection and stability. This report highlights the advantages of a comprehensive strategy for managing repeated sternal dehiscence.</p>","PeriodicalId":34499,"journal":{"name":"Journal of Chest Surgery","volume":" ","pages":"60-64"},"PeriodicalIF":0.0000,"publicationDate":"2025-03-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11884975/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Chest Surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5090/jcs.24.087","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/2/20 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0
Abstract
Sternal wound dehiscence after cardiac surgery is usually accompanied by a high morbidity and mortality rate. When sternal rewiring fails, rigid fixation systems may be used for sternal reconstruction. We report a case involving a female patient with multiple risk factors for sternal dehiscence who underwent a coronary artery bypass graft procedure. Postoperatively, she experienced sternal dehiscence that necessitated primary rewiring. Despite the surgical intervention and clinical optimization, the sternal wound dehiscence recurred. The patient experienced severe chest pain and thoracic instability, presenting with complete non-union of the sternal segments and right ventricular protrusion. Given the symptoms and the risk of both direct and indirect trauma to the heart, the multidisciplinary team opted to reinforce the anterior chest wall with a pre-planned titanium prosthesis to provide protection and stability. This report highlights the advantages of a comprehensive strategy for managing repeated sternal dehiscence.