Local delivery of steroids to inner ear via medical device INCAT (the inner ear Catheter) in partial deafness patients during cochlear implantation - preliminary results and a feasibility study.

Magdalena B Skarżyńska, Elżbieta Gos, Piotr H Skarżyński, Artur Lorens, Adam Walkowiak, Henryk Skarżyński
{"title":"Local delivery of steroids to inner ear via medical device INCAT (the inner ear Catheter) in partial deafness patients during cochlear implantation - preliminary results and a feasibility study.","authors":"Magdalena B Skarżyńska, Elżbieta Gos, Piotr H Skarżyński, Artur Lorens, Adam Walkowiak, Henryk Skarżyński","doi":"10.1080/17425247.2025.2466773","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The primary aim was to assess the effectiveness and safety of three different algorithms of using steroids and inner ear catheter (INCAT) Medel® in partial deafness patients who underwent cochlear implantation. The secondary goal was the assessment of the impact of the depth of INCAT on hearing preservation after cochlear implantation.</p><p><strong>Research design and methods: </strong>There were three algorithms of steroid administration: 1) methylprednisolone 62.5 mg/ml (solution), 3 patients; 2) methylprednisolone 40 mg/ml (suspension), 4 patients; 3) dexamethasone 4 mg/ml (solution), 3 patients. Pure tone audiometry (0.125-8 kHz) was performed preoperatively, 1 and 6 months post-op. Hearing preservation was assessed according to the HEARRING group formula. Impedance measurements were taken at two days, 1 and 6 months after surgery.</p><p><strong>Results: </strong>Patients treated with methylprednisolone 40 mg/ml in suspension showed the best hearing preservation (50% complete and 50% partial preservation) 1 month post-op and later remained the most favorable. The lowest impedance was found in this group both 1 and 6 months post-op. A shorter INCAT insertion depth appeared to be more favorable than a longer one.</p><p><strong>Conclusion: </strong>Our results suggest that patients treated with methylprednisolone 40 mg/ml (suspension) had better hearing outcomes compared to the other two medications.</p>","PeriodicalId":94004,"journal":{"name":"Expert opinion on drug delivery","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2025-02-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Expert opinion on drug delivery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/17425247.2025.2466773","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: The primary aim was to assess the effectiveness and safety of three different algorithms of using steroids and inner ear catheter (INCAT) Medel® in partial deafness patients who underwent cochlear implantation. The secondary goal was the assessment of the impact of the depth of INCAT on hearing preservation after cochlear implantation.

Research design and methods: There were three algorithms of steroid administration: 1) methylprednisolone 62.5 mg/ml (solution), 3 patients; 2) methylprednisolone 40 mg/ml (suspension), 4 patients; 3) dexamethasone 4 mg/ml (solution), 3 patients. Pure tone audiometry (0.125-8 kHz) was performed preoperatively, 1 and 6 months post-op. Hearing preservation was assessed according to the HEARRING group formula. Impedance measurements were taken at two days, 1 and 6 months after surgery.

Results: Patients treated with methylprednisolone 40 mg/ml in suspension showed the best hearing preservation (50% complete and 50% partial preservation) 1 month post-op and later remained the most favorable. The lowest impedance was found in this group both 1 and 6 months post-op. A shorter INCAT insertion depth appeared to be more favorable than a longer one.

Conclusion: Our results suggest that patients treated with methylprednisolone 40 mg/ml (suspension) had better hearing outcomes compared to the other two medications.

求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信