Comparing Low-Frequency Hearing Thresholds between Insert Earphones and Headphones in Ears with Tympanic Membrane Perforations.

IF 1.8 Q2 OTORHINOLARYNGOLOGY
OTO Open Pub Date : 2025-02-12 eCollection Date: 2025-01-01 DOI:10.1002/oto2.70045
Anna Hsu, Sarah H Al Nemer, Peter Kfoury, Jordan Stout, Anna Holley, Caitlin Stone, Matthew Firpo, Albert Park
{"title":"Comparing Low-Frequency Hearing Thresholds between Insert Earphones and Headphones in Ears with Tympanic Membrane Perforations.","authors":"Anna Hsu, Sarah H Al Nemer, Peter Kfoury, Jordan Stout, Anna Holley, Caitlin Stone, Matthew Firpo, Albert Park","doi":"10.1002/oto2.70045","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To compare hearing thresholds at 250 and 500 Hz in pediatric patients with tympanic membrane perforations (TMP) using RadioEar IP30 insert earphones and RadioEar TDH50s 3045 supra-aural headphones.</p><p><strong>Study design: </strong>Prospective clinical pilot study.</p><p><strong>Setting: </strong>Primary Children's Hospital, Utah.</p><p><strong>Methods: </strong>Children (<18 years of age) were prospectively enrolled into 2 groups based on the presence of TMPs (no TMP, TMP). Hearing thresholds were measured at 250 and 500 Hz using RadioEar IP30 insert earphones and RadioEar TDH50s 3045 supra-aural headphones for all participants.</p><p><strong>Results: </strong>At 250 and 500 Hz, hearing thresholds were significantly higher when recorded with insert earphones than with supra-aural headphones in pediatric participants with TMPs. At 250 Hz, thresholds obtained with inserts were 14.7 ± 7.2 dB (<i>P</i> < .001) higher than thresholds obtained with supra-aural headphones and 8.0 ± 7.5 dB higher (<i>P</i> < .01) at 500 Hz.</p><p><strong>Conclusion: </strong>Low-frequency hearing thresholds were significantly higher when measured with insert earphones in patients with TMPsbut not in patients without TMPs. A diagnosis of low-frequency hearing loss must be interpreted with caution when using insert earphones in participants with TMPs.</p>","PeriodicalId":19697,"journal":{"name":"OTO Open","volume":"9 1","pages":"e70045"},"PeriodicalIF":1.8000,"publicationDate":"2025-02-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11815708/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"OTO Open","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1002/oto2.70045","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"OTORHINOLARYNGOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: To compare hearing thresholds at 250 and 500 Hz in pediatric patients with tympanic membrane perforations (TMP) using RadioEar IP30 insert earphones and RadioEar TDH50s 3045 supra-aural headphones.

Study design: Prospective clinical pilot study.

Setting: Primary Children's Hospital, Utah.

Methods: Children (<18 years of age) were prospectively enrolled into 2 groups based on the presence of TMPs (no TMP, TMP). Hearing thresholds were measured at 250 and 500 Hz using RadioEar IP30 insert earphones and RadioEar TDH50s 3045 supra-aural headphones for all participants.

Results: At 250 and 500 Hz, hearing thresholds were significantly higher when recorded with insert earphones than with supra-aural headphones in pediatric participants with TMPs. At 250 Hz, thresholds obtained with inserts were 14.7 ± 7.2 dB (P < .001) higher than thresholds obtained with supra-aural headphones and 8.0 ± 7.5 dB higher (P < .01) at 500 Hz.

Conclusion: Low-frequency hearing thresholds were significantly higher when measured with insert earphones in patients with TMPsbut not in patients without TMPs. A diagnosis of low-frequency hearing loss must be interpreted with caution when using insert earphones in participants with TMPs.

求助全文
约1分钟内获得全文 求助全文
来源期刊
OTO Open
OTO Open Medicine-Surgery
CiteScore
2.70
自引率
0.00%
发文量
115
审稿时长
15 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信