Comparative evaluation of the performance of orthodontic retainers using different surface protocols: an in vitro study.

IF 2.1 4区 医学 Q3 ENGINEERING, BIOMEDICAL
Merve Kurnaz, Ali Arslan Nazan, Feyza Eraydın
{"title":"Comparative evaluation of the performance of orthodontic retainers using different surface protocols: an in vitro study.","authors":"Merve Kurnaz, Ali Arslan Nazan, Feyza Eraydın","doi":"10.1007/s10103-025-04348-4","DOIUrl":null,"url":null,"abstract":"<p><p>This study aims to assess the in vitro durability of Nitinol retainers, manufactured using computer-aided methods with hydrophilic or superhydrophilic surfaces to reduce debonding, alongside a commonly used composite adhesive. The 112 lower incisor teeth were embedded in blocks in pairs. Retainer wires were made up of 0.018 × 0.018 inch Nickel Titanium alloy(G4™ Nickel Titanium G&H Orthodontics, USA) by bending a robot arm. A total of 16 teeth(8 blocks) were used for each of the mentioned 7 groups Ni-Ti Retainer; Laser Textured Ni-Ti Retainer; Laser Texturing and Atmospheric Plasma Applicated Ni-Ti Retainer; Atmospheric Plasma Applicated Ni-Ti Retainer; Laser Texturing and Atmospheric Plasma Applicated Ni-Ti Retainer*2; Laser Texturing and Atmospheric Plasma Applicated Ni-Ti Retainer*3; SS-0.0018\"(Morelli, Brazil). Transbond LR(3 M Unitek, California) was used. The shear bond strength tests were conducted. The Kruskal-Wallis H test was employed, pairwise comparisons followed by Dunn's test with Bonferroni correction as a post-hoc analysis. There was no statistically significant difference between the groups for maximum force and maximum stress(p > 0.05). However, a significant difference was found in maximum elongation (p:0.0023). Pairwise comparisons highlighted significantly higher elongation values in the SS-0.0018\" group. The stainless-steel wire demonstrated higher elongation values, which may offer clinical advantages in cases with higher occlusal forces and periodontal problems due to its material flexibility. Laser Texturing and Atmospheric Plasma Applied Ni-Ti Retainers exhibited higher test performance. Surface treatments applied to CAD/CAM retainers can provide an advantage by enhancing bond strength, potentially reducing the risk of debonding. These findings underline the importance of material selection and surface treatments in optimizing fixed retention strategies for long-term clinical success.</p>","PeriodicalId":17978,"journal":{"name":"Lasers in Medical Science","volume":"40 1","pages":"86"},"PeriodicalIF":2.1000,"publicationDate":"2025-02-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11825553/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Lasers in Medical Science","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1007/s10103-025-04348-4","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

This study aims to assess the in vitro durability of Nitinol retainers, manufactured using computer-aided methods with hydrophilic or superhydrophilic surfaces to reduce debonding, alongside a commonly used composite adhesive. The 112 lower incisor teeth were embedded in blocks in pairs. Retainer wires were made up of 0.018 × 0.018 inch Nickel Titanium alloy(G4™ Nickel Titanium G&H Orthodontics, USA) by bending a robot arm. A total of 16 teeth(8 blocks) were used for each of the mentioned 7 groups Ni-Ti Retainer; Laser Textured Ni-Ti Retainer; Laser Texturing and Atmospheric Plasma Applicated Ni-Ti Retainer; Atmospheric Plasma Applicated Ni-Ti Retainer; Laser Texturing and Atmospheric Plasma Applicated Ni-Ti Retainer*2; Laser Texturing and Atmospheric Plasma Applicated Ni-Ti Retainer*3; SS-0.0018"(Morelli, Brazil). Transbond LR(3 M Unitek, California) was used. The shear bond strength tests were conducted. The Kruskal-Wallis H test was employed, pairwise comparisons followed by Dunn's test with Bonferroni correction as a post-hoc analysis. There was no statistically significant difference between the groups for maximum force and maximum stress(p > 0.05). However, a significant difference was found in maximum elongation (p:0.0023). Pairwise comparisons highlighted significantly higher elongation values in the SS-0.0018" group. The stainless-steel wire demonstrated higher elongation values, which may offer clinical advantages in cases with higher occlusal forces and periodontal problems due to its material flexibility. Laser Texturing and Atmospheric Plasma Applied Ni-Ti Retainers exhibited higher test performance. Surface treatments applied to CAD/CAM retainers can provide an advantage by enhancing bond strength, potentially reducing the risk of debonding. These findings underline the importance of material selection and surface treatments in optimizing fixed retention strategies for long-term clinical success.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Lasers in Medical Science
Lasers in Medical Science 医学-工程:生物医学
CiteScore
4.50
自引率
4.80%
发文量
192
审稿时长
3-8 weeks
期刊介绍: Lasers in Medical Science (LIMS) has established itself as the leading international journal in the rapidly expanding field of medical and dental applications of lasers and light. It provides a forum for the publication of papers on the technical, experimental, and clinical aspects of the use of medical lasers, including lasers in surgery, endoscopy, angioplasty, hyperthermia of tumors, and photodynamic therapy. In addition to medical laser applications, LIMS presents high-quality manuscripts on a wide range of dental topics, including aesthetic dentistry, endodontics, orthodontics, and prosthodontics. The journal publishes articles on the medical and dental applications of novel laser technologies, light delivery systems, sensors to monitor laser effects, basic laser-tissue interactions, and the modeling of laser-tissue interactions. Beyond laser applications, LIMS features articles relating to the use of non-laser light-tissue interactions.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信