Application of the three-phase T1-derived model in staging liver fibrosis in chronic hepatitis: a comparative study with magnetic resonance elastography.
IF 2.3 3区 医学Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Zhanao Meng, Sidong Xie, Xue Lin, Jian Cao, Sisi Deng, Tao Luo, Xiaolei Li, Yue Zhang, Ke Zhang, Xuan Zhu, Na Cheng, Yingkun Chen, Tianhao Tang, Qing Xiang, Yahao Guo, Wenjie Tang, Jie Qin
{"title":"Application of the three-phase T1-derived model in staging liver fibrosis in chronic hepatitis: a comparative study with magnetic resonance elastography.","authors":"Zhanao Meng, Sidong Xie, Xue Lin, Jian Cao, Sisi Deng, Tao Luo, Xiaolei Li, Yue Zhang, Ke Zhang, Xuan Zhu, Na Cheng, Yingkun Chen, Tianhao Tang, Qing Xiang, Yahao Guo, Wenjie Tang, Jie Qin","doi":"10.1007/s00261-025-04823-0","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>This study aims to evaluate the accuracy of a three-phase T1-derived model in staging liver fibrosis in patients with chronic hepatitis, in comparison with magnetic resonance elastography (MRE).</p><p><strong>Methods: </strong>A total of 174 patients with chronic hepatitis were enrolled. The acquisition of three-phase longitudinal relaxation times (T1-Unenh = A, T1-DLP = B, T1HBP = C) from magnetic resonance enhancement examinations, as well as magnetic resonance elastography (MRE) and liver biopsy information for patients.Binary logistic regression was employed to construct models ABC. The diagnostic performance of these models was evaluated using the receiver operating characteristic (ROC) curve and DeLong's test. Furthermore, the MRE and ABC models were subjected to a comprehensive analysis through 10-fold cross-validation.</p><p><strong>Results: </strong>In all liver fibrosis stages (≥ F1-≥F4), both MRE and the ABC model showed moderate correlation with METAVIR fibrosis staging, with significant differences between groups (all P < 0.05). The area under the curve (AUC) for each group of the ABC model was above 0.84. DeLong's test indicated that in the ≥ F2, ≥F3, and ≥ F4 groups, the ABC model was comparable to MRE (all P > 0.05). Ten-fold cross-validation further confirmed that only in the ≥ F3 group did the ABC model outperform MRE in terms of comprehensive performance.</p><p><strong>Conclusion: </strong>This study successfully validated the effectiveness of the three-phase T1-derived model in staging liver fibrosis in patients with chronic hepatitis. In stages ≥ F2, ≥F3, and ≥ F4, it is comparable to MRE, especially showing superior application value in the ≥ F3 stage.</p>","PeriodicalId":7126,"journal":{"name":"Abdominal Radiology","volume":" ","pages":""},"PeriodicalIF":2.3000,"publicationDate":"2025-02-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Abdominal Radiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00261-025-04823-0","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0
Abstract
Objective: This study aims to evaluate the accuracy of a three-phase T1-derived model in staging liver fibrosis in patients with chronic hepatitis, in comparison with magnetic resonance elastography (MRE).
Methods: A total of 174 patients with chronic hepatitis were enrolled. The acquisition of three-phase longitudinal relaxation times (T1-Unenh = A, T1-DLP = B, T1HBP = C) from magnetic resonance enhancement examinations, as well as magnetic resonance elastography (MRE) and liver biopsy information for patients.Binary logistic regression was employed to construct models ABC. The diagnostic performance of these models was evaluated using the receiver operating characteristic (ROC) curve and DeLong's test. Furthermore, the MRE and ABC models were subjected to a comprehensive analysis through 10-fold cross-validation.
Results: In all liver fibrosis stages (≥ F1-≥F4), both MRE and the ABC model showed moderate correlation with METAVIR fibrosis staging, with significant differences between groups (all P < 0.05). The area under the curve (AUC) for each group of the ABC model was above 0.84. DeLong's test indicated that in the ≥ F2, ≥F3, and ≥ F4 groups, the ABC model was comparable to MRE (all P > 0.05). Ten-fold cross-validation further confirmed that only in the ≥ F3 group did the ABC model outperform MRE in terms of comprehensive performance.
Conclusion: This study successfully validated the effectiveness of the three-phase T1-derived model in staging liver fibrosis in patients with chronic hepatitis. In stages ≥ F2, ≥F3, and ≥ F4, it is comparable to MRE, especially showing superior application value in the ≥ F3 stage.
期刊介绍:
Abdominal Radiology seeks to meet the professional needs of the abdominal radiologist by publishing clinically pertinent original, review and practice related articles on the gastrointestinal and genitourinary tracts and abdominal interventional and radiologic procedures. Case reports are generally not accepted unless they are the first report of a new disease or condition, or part of a special solicited section.
Reasons to Publish Your Article in Abdominal Radiology:
· Official journal of the Society of Abdominal Radiology (SAR)
· Published in Cooperation with:
European Society of Gastrointestinal and Abdominal Radiology (ESGAR)
European Society of Urogenital Radiology (ESUR)
Asian Society of Abdominal Radiology (ASAR)
· Efficient handling and Expeditious review
· Author feedback is provided in a mentoring style
· Global readership
· Readers can earn CME credits