Efficacy of Biliary Brush Cytology With Rapid On-Site Cytological Evaluation for the Detection of Malignant Biliary Strictures.

IF 3.7 3区 医学 Q2 GASTROENTEROLOGY & HEPATOLOGY
Il Sang Shin, Jun Ho Myeong, Jong Ho Moon, Yun Nah Lee, Jae Woo Park, Hee Kyung Kim, Jae Kook Yang, Tae Hoon Lee, Young Deok Cho, Sang-Heum Park
{"title":"Efficacy of Biliary Brush Cytology With Rapid On-Site Cytological Evaluation for the Detection of Malignant Biliary Strictures.","authors":"Il Sang Shin, Jun Ho Myeong, Jong Ho Moon, Yun Nah Lee, Jae Woo Park, Hee Kyung Kim, Jae Kook Yang, Tae Hoon Lee, Young Deok Cho, Sang-Heum Park","doi":"10.1111/jgh.16865","DOIUrl":null,"url":null,"abstract":"<p><strong>Background and aims: </strong>Brush cytology is a widely used diagnostic method in conjunction with intraductal biopsies during endoscopic retrograde cholangiopancreatography, but its diagnostic yield remains a limitation. This study evaluated the efficacy of biliary cytology using a newly developed brush device with rapid on-site cytological evaluation (ROSE) for detecting malignant biliary strictures (MBSs).</p><p><strong>Methods: </strong>In total, 58 patients with suspected intrinsic MBS identified by intraductal ultrasound were enrolled. After achieving tissue sampling with ROSE through a maximum of two brushing passes, a transpapillary forceps biopsy (TPB) was performed. The primary outcome was diagnostic accuracy, and the secondary outcomes were technical success, sampling adequacy, and procedure-related adverse events.</p><p><strong>Results: </strong>Biliary cytology with ROSE was technically successful in all patients (58/58), with a sampling adequacy of 96.6% (56/58). The technical success and sampling adequacy of TPB were 94.8% (55/58) and 91.4% (53/58), respectively. Brush cytology with ROSE and TPB yielded sensitivity rates of 91.8% and 85.7%, specificity rates of 88.9% for both, and accuracy rates of 88.9% for both. The receiver operating characteristic curve comparing the diagnostic accuracies of brush cytology with ROSE and TPB combined versus TPB alone showed a significantly higher value for the combined approach (0.93) than TPB alone (0.87) (p = 0.010).</p><p><strong>Conclusion: </strong>Biliary brush cytology using a novel brush device with ROSE is effective and can be used complementarily to TPB in patients with suspected MBS.</p>","PeriodicalId":15877,"journal":{"name":"Journal of Gastroenterology and Hepatology","volume":" ","pages":""},"PeriodicalIF":3.7000,"publicationDate":"2025-02-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Gastroenterology and Hepatology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/jgh.16865","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"GASTROENTEROLOGY & HEPATOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background and aims: Brush cytology is a widely used diagnostic method in conjunction with intraductal biopsies during endoscopic retrograde cholangiopancreatography, but its diagnostic yield remains a limitation. This study evaluated the efficacy of biliary cytology using a newly developed brush device with rapid on-site cytological evaluation (ROSE) for detecting malignant biliary strictures (MBSs).

Methods: In total, 58 patients with suspected intrinsic MBS identified by intraductal ultrasound were enrolled. After achieving tissue sampling with ROSE through a maximum of two brushing passes, a transpapillary forceps biopsy (TPB) was performed. The primary outcome was diagnostic accuracy, and the secondary outcomes were technical success, sampling adequacy, and procedure-related adverse events.

Results: Biliary cytology with ROSE was technically successful in all patients (58/58), with a sampling adequacy of 96.6% (56/58). The technical success and sampling adequacy of TPB were 94.8% (55/58) and 91.4% (53/58), respectively. Brush cytology with ROSE and TPB yielded sensitivity rates of 91.8% and 85.7%, specificity rates of 88.9% for both, and accuracy rates of 88.9% for both. The receiver operating characteristic curve comparing the diagnostic accuracies of brush cytology with ROSE and TPB combined versus TPB alone showed a significantly higher value for the combined approach (0.93) than TPB alone (0.87) (p = 0.010).

Conclusion: Biliary brush cytology using a novel brush device with ROSE is effective and can be used complementarily to TPB in patients with suspected MBS.

求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
7.90
自引率
2.40%
发文量
326
审稿时长
2.3 months
期刊介绍: Journal of Gastroenterology and Hepatology is produced 12 times per year and publishes peer-reviewed original papers, reviews and editorials concerned with clinical practice and research in the fields of hepatology, gastroenterology and endoscopy. Papers cover the medical, radiological, pathological, biochemical, physiological and historical aspects of the subject areas. All submitted papers are reviewed by at least two referees expert in the field of the submitted paper.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信