Sarah Hinterberger, Sophie Schneider, Martin Kallab, Olivia Murauer, Anna-Sophie Reisinger, Matthias Bolz, Clemens A Strohmaier
{"title":"Surgical success 2 years after preserflo microshunt implantation: real world data from a single eye care centre.","authors":"Sarah Hinterberger, Sophie Schneider, Martin Kallab, Olivia Murauer, Anna-Sophie Reisinger, Matthias Bolz, Clemens A Strohmaier","doi":"10.1007/s00417-025-06739-3","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate real world efficacy and safety of the Preserflo MicroShunt (PM) in a heterogenous patient cohort at a single tertiary eye care centre.</p><p><strong>Patients and methods: </strong>A retrospective data analysis of PM implantations between 2019 and 2022 was performed. Primary outcome measures were complete-, qualified-, and overall- success as well as failure defined according to the WGA criteria. Secondary outcomes were intraocular pressure (IOP) and IOP lowering medications.</p><p><strong>Result: </strong>38 patients were included in the study. After 24 months, complete success was achieved in 31.58% and qualified success in 28.95% whereas 39.47% were classified as failure. IOP was reduced by 55.2% from mean 25.57 ± 10.03 mmHg at baseline to 11.45 ± 3.37 mmHg two years postoperative in eyes classified as success. The number of IOP lowering medications was reduced from 2.73 ± 1.33 before surgery to 1.14 ± 1.31 at the end of the follow-up period.</p><p><strong>Conclusion: </strong>Two years postoperatively an overall success rate of 60.53% was achieved and a significant IOP reduction was preserved over the complete two years follow-up time.</p><p><strong>Key messages: </strong>What is known Multiple studies have proven that the Preserflo MicroShunt is a safe and efficient surgical procedure to lower intraocular pressure. The success rates reported for primary open angle glaucoma are comparable to trabeculectomy. What is new Real world data including different glaucoma subtypes at one tertiary care centre are reported with a two-year follow up. An overall surgical success rate of 60.53% was achieved. An intraocular pressure reduction of 50.2% was sustained over the two years follow up period.</p>","PeriodicalId":12795,"journal":{"name":"Graefe’s Archive for Clinical and Experimental Ophthalmology","volume":" ","pages":""},"PeriodicalIF":2.4000,"publicationDate":"2025-02-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Graefe’s Archive for Clinical and Experimental Ophthalmology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00417-025-06739-3","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: To evaluate real world efficacy and safety of the Preserflo MicroShunt (PM) in a heterogenous patient cohort at a single tertiary eye care centre.
Patients and methods: A retrospective data analysis of PM implantations between 2019 and 2022 was performed. Primary outcome measures were complete-, qualified-, and overall- success as well as failure defined according to the WGA criteria. Secondary outcomes were intraocular pressure (IOP) and IOP lowering medications.
Result: 38 patients were included in the study. After 24 months, complete success was achieved in 31.58% and qualified success in 28.95% whereas 39.47% were classified as failure. IOP was reduced by 55.2% from mean 25.57 ± 10.03 mmHg at baseline to 11.45 ± 3.37 mmHg two years postoperative in eyes classified as success. The number of IOP lowering medications was reduced from 2.73 ± 1.33 before surgery to 1.14 ± 1.31 at the end of the follow-up period.
Conclusion: Two years postoperatively an overall success rate of 60.53% was achieved and a significant IOP reduction was preserved over the complete two years follow-up time.
Key messages: What is known Multiple studies have proven that the Preserflo MicroShunt is a safe and efficient surgical procedure to lower intraocular pressure. The success rates reported for primary open angle glaucoma are comparable to trabeculectomy. What is new Real world data including different glaucoma subtypes at one tertiary care centre are reported with a two-year follow up. An overall surgical success rate of 60.53% was achieved. An intraocular pressure reduction of 50.2% was sustained over the two years follow up period.
期刊介绍:
Graefe''s Archive for Clinical and Experimental Ophthalmology is a distinguished international journal that presents original clinical reports and clini-cally relevant experimental studies. Founded in 1854 by Albrecht von Graefe to serve as a source of useful clinical information and a stimulus for discussion, the journal has published articles by leading ophthalmologists and vision research scientists for more than a century. With peer review by an international Editorial Board and prompt English-language publication, Graefe''s Archive provides rapid dissemination of clinical and clinically related experimental information.