Comparison of VCare and SecuFix uterine manipulator in total laparoscopic hysterectomy: a prospective randomized trial.

Emre Mat, Esra Keles, Pınar Yıldız, Murat Levent Dereli, Fatih Şanlıkan, Gazi Yıldız
{"title":"Comparison of VCare and SecuFix uterine manipulator in total laparoscopic hysterectomy: a prospective randomized trial.","authors":"Emre Mat, Esra Keles, Pınar Yıldız, Murat Levent Dereli, Fatih Şanlıkan, Gazi Yıldız","doi":"10.5603/gpl.101589","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>To compare the Vcare and SecuFix uterine manipulators (UM) used in total laparoscopic hysterectomy (TLH) with regard to operating time, duration of hospital stay, the time for insertion of the manipulator, time for completion of colpotomy, and maintenance of pneumoperitoneum, estimated blood loss, and perioperative complications.</p><p><strong>Material and methods: </strong>This prospective, single-center, randomized controlled trial was conducted on patients who underwent TLH for benign indications between June 2023 and January 2024. Patients were randomized to either the Vcare UM or SecuFix UM group. Both groups were compared for operative time, colpotomy time, intrauterine manipulator insertion time, pneumoperitoneum maintenance, blood loss, complications, and length of hospital stay.</p><p><strong>Results: </strong>A total of 100 patients were enrolled, 50 with VcareUM and 50 with SecuFix UM. SecuFix UM demonstrated shorter colpotomy time (p < 0.001) and better pneumoperitoneum maintenance (p = 0.008) compared to VCare. VCare had shorter insertion time (p = 0.001) but a higher uterine rupture rate (p = 0.001). No significant differences were found in operative time, blood loss, complications, or length of hospital stay (p > 0.05).</p><p><strong>Conclusions: </strong>SecuFix may offer advantages in colpotomy and pneumoperitoneum maintenance during TLH compared to VCare. The Vcare UM demonstrated a shorter insertion time than the SecuFix UMs, yet a higher rate of uterine rupture was observed with its placement.</p>","PeriodicalId":94021,"journal":{"name":"Ginekologia polska","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2025-02-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ginekologia polska","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5603/gpl.101589","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: To compare the Vcare and SecuFix uterine manipulators (UM) used in total laparoscopic hysterectomy (TLH) with regard to operating time, duration of hospital stay, the time for insertion of the manipulator, time for completion of colpotomy, and maintenance of pneumoperitoneum, estimated blood loss, and perioperative complications.

Material and methods: This prospective, single-center, randomized controlled trial was conducted on patients who underwent TLH for benign indications between June 2023 and January 2024. Patients were randomized to either the Vcare UM or SecuFix UM group. Both groups were compared for operative time, colpotomy time, intrauterine manipulator insertion time, pneumoperitoneum maintenance, blood loss, complications, and length of hospital stay.

Results: A total of 100 patients were enrolled, 50 with VcareUM and 50 with SecuFix UM. SecuFix UM demonstrated shorter colpotomy time (p < 0.001) and better pneumoperitoneum maintenance (p = 0.008) compared to VCare. VCare had shorter insertion time (p = 0.001) but a higher uterine rupture rate (p = 0.001). No significant differences were found in operative time, blood loss, complications, or length of hospital stay (p > 0.05).

Conclusions: SecuFix may offer advantages in colpotomy and pneumoperitoneum maintenance during TLH compared to VCare. The Vcare UM demonstrated a shorter insertion time than the SecuFix UMs, yet a higher rate of uterine rupture was observed with its placement.

求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信