Implant scanning workflows: Accuracy of registration methods for integrating intraoral scans containing soft tissue and tooth position information.

IF 4.3 2区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE
Marta Revilla-León, Panagiotis Ntovas, Abdul B Barmak, Vygandas Rutkunas, John C Kois
{"title":"Implant scanning workflows: Accuracy of registration methods for integrating intraoral scans containing soft tissue and tooth position information.","authors":"Marta Revilla-León, Panagiotis Ntovas, Abdul B Barmak, Vygandas Rutkunas, John C Kois","doi":"10.1016/j.prosdent.2025.01.017","DOIUrl":null,"url":null,"abstract":"<p><strong>Statement of problem: </strong>An implant scanning workflow involves recording different intraoral scans containing all the information needed to fabricate an implant-supported prosthesis. The accuracy of these implant scanning workflow registration methods remains unknown.</p><p><strong>Purpose: </strong>The purpose of this in vitro study was to compare the accuracy of different implant scanning workflows for registering the soft tissue and tooth position information scans recorded by using 5 intraoral scanners (IOSs).</p><p><strong>Material and methods: </strong>A maxillary edentulous stone cast with 6 implant abutment analogs (MultiUnit Abutment Replica) and 2 screw-retained implant-supported interim restorations (from the right first molar to the left canine and from the left first premolar to the left first molar) were obtained. Three markers were attached on the palatal surface of the cast on the anterior palatine raphe and right and left first molar positions, and 4 markers were attached on the palatal surface of the right and left second premolar and right and left lateral incisor of the interim prostheses. Afterwards, 5 composite resin (CR) reference landmarks were created on the palatal surface of the cast on the anterior palatine raphe, right and left first premolar, and right and left first molar. Additionally, a screw was placed in the posterior palatine raphe, simulating a temporary anchorage device (TAD). The interim prostheses were positioned in the implant analogs of the cast and digitized by using a laboratory scanner (T710). Five groups were created depending on the IOS: TRIOS 5, i700, Elite, iTero, and Primescan groups. A tooth position, soft tissue information, and soft tissue with existing teeth scans were obtained by using each IOS. Six subgroups were created depending on the reference landmarks used to register the scans: 3 or 5 CR landmarks (3CR or 5RC subgroup, respectively), existing teeth (teeth subgroup), existing teeth combined with 2 CR landmarks (teeth+2CR subgroup), TAD (TAD subgroup), TAD combined with 1 CR landmark (TAD+1CR subgroup). Twelve linear measurements were performed on the control scans and on each specimen among the 7 markers. Trueness was analyzed by using 2-way ANOVA and the pairwise comparison Tukey tests (α=.05). Precision was evaluated by using the Levene and pairwise comparisons tests (α=.05).</p><p><strong>Results: </strong>Trueness discrepancies were found among the groups (P<.001) and subgroups (P<.001), with a significant group*subgroup interaction (P=.004). The Tukey test showed that the Primescan and iTero systems obtained worse trueness than the other groups. Also, the TAD and Teeth subgroups obtained worse trueness than the other subgroups tested. All the groups and subgroups were significantly different from each other (P<.05).</p><p><strong>Conclusions: </strong>The IOS and reference landmarks tested impacted the trueness and precision of the registration of soft tissue and tooth position information scans.</p>","PeriodicalId":16866,"journal":{"name":"Journal of Prosthetic Dentistry","volume":" ","pages":""},"PeriodicalIF":4.3000,"publicationDate":"2025-02-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Prosthetic Dentistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.prosdent.2025.01.017","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Statement of problem: An implant scanning workflow involves recording different intraoral scans containing all the information needed to fabricate an implant-supported prosthesis. The accuracy of these implant scanning workflow registration methods remains unknown.

Purpose: The purpose of this in vitro study was to compare the accuracy of different implant scanning workflows for registering the soft tissue and tooth position information scans recorded by using 5 intraoral scanners (IOSs).

Material and methods: A maxillary edentulous stone cast with 6 implant abutment analogs (MultiUnit Abutment Replica) and 2 screw-retained implant-supported interim restorations (from the right first molar to the left canine and from the left first premolar to the left first molar) were obtained. Three markers were attached on the palatal surface of the cast on the anterior palatine raphe and right and left first molar positions, and 4 markers were attached on the palatal surface of the right and left second premolar and right and left lateral incisor of the interim prostheses. Afterwards, 5 composite resin (CR) reference landmarks were created on the palatal surface of the cast on the anterior palatine raphe, right and left first premolar, and right and left first molar. Additionally, a screw was placed in the posterior palatine raphe, simulating a temporary anchorage device (TAD). The interim prostheses were positioned in the implant analogs of the cast and digitized by using a laboratory scanner (T710). Five groups were created depending on the IOS: TRIOS 5, i700, Elite, iTero, and Primescan groups. A tooth position, soft tissue information, and soft tissue with existing teeth scans were obtained by using each IOS. Six subgroups were created depending on the reference landmarks used to register the scans: 3 or 5 CR landmarks (3CR or 5RC subgroup, respectively), existing teeth (teeth subgroup), existing teeth combined with 2 CR landmarks (teeth+2CR subgroup), TAD (TAD subgroup), TAD combined with 1 CR landmark (TAD+1CR subgroup). Twelve linear measurements were performed on the control scans and on each specimen among the 7 markers. Trueness was analyzed by using 2-way ANOVA and the pairwise comparison Tukey tests (α=.05). Precision was evaluated by using the Levene and pairwise comparisons tests (α=.05).

Results: Trueness discrepancies were found among the groups (P<.001) and subgroups (P<.001), with a significant group*subgroup interaction (P=.004). The Tukey test showed that the Primescan and iTero systems obtained worse trueness than the other groups. Also, the TAD and Teeth subgroups obtained worse trueness than the other subgroups tested. All the groups and subgroups were significantly different from each other (P<.05).

Conclusions: The IOS and reference landmarks tested impacted the trueness and precision of the registration of soft tissue and tooth position information scans.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Prosthetic Dentistry
Journal of Prosthetic Dentistry 医学-牙科与口腔外科
CiteScore
7.00
自引率
13.00%
发文量
599
审稿时长
69 days
期刊介绍: The Journal of Prosthetic Dentistry is the leading professional journal devoted exclusively to prosthetic and restorative dentistry. The Journal is the official publication for 24 leading U.S. international prosthodontic organizations. The monthly publication features timely, original peer-reviewed articles on the newest techniques, dental materials, and research findings. The Journal serves prosthodontists and dentists in advanced practice, and features color photos that illustrate many step-by-step procedures. The Journal of Prosthetic Dentistry is included in Index Medicus and CINAHL.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信